15. OUTER CLEANING
WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING
THE POWER PLUG BEFORE CLEANING.
For a good preservation of the cabinet’s body a periodical cleaning is necessary.
1.
EXTERNAL BODY:
When necessary, the external body should be cleaned with a cloth
and a neutral soap and water solution.
2.
STAINLESS STEEL SURFACES:
Wash with warm water and mild detergent, rinse well and
dry with soft cloth. Avoid scouring pads etc. which will spoil the finish of the stainless steel.
3.
SURFACES IN PLASTIC MATERIAL:
Wash with warm water and mild detergent, rinse
well and dry with soft cloth; under no circumstances should alcohol, methylated spirits
or solvents be used.
4.
GLASS SURFACES:
Only use products specifically designed for glass cleaning; It is not
advisable to use ordinary water which can leave a film of calcium on the surface of the glass.
WARNING!
Do not use jet of water to clean the cabinet: electrical wiring
could be damaged.
WARNING! Never use mechanical devices or any other means to accelerate
the defrosting process, other than those recommended by the manufacturer.
16. MAINTENANCE
WARNING!
Maintenance must be carried out by technical staff trained and
enabled for intervention on the flammable refrigerants.
WARNING!
Any work carried out on the appliance by the user strictly requires
the power plug being disconnected from the mains socket.
ATTENTION! Use protective shoes and gloves during maintenance operations.
Any other maintenance operation not planned in the previous points should
be carried out by the support centres authorised by our dealers or by
qualified staff.
OPERATION
FREQUENCY
ORDINARY /
EXTRAORDINARY
MAINTENANCE
AUTHORISED
STAFF
Cleaning of external surfaces
Based on use
Ordinary
User
Cleaning of accessible internal parts (no use of tools)
Based on use
Ordinary
User
Seals intactness check
Yearly *
Ordinary
Technical support
Water collection tank cleaning
Yearly *
Ordinary
Technical support
Checking and cleaning the condenser if necessary
Yearly *
Ordinary
Technical support
Replacement components and parts
-
Extraordinary
Technical support
* Recommended frequency for optimal counter operation and maintenance of full efficiency.