![IAP SF-1000 Скачать руководство пользователя страница 10](http://html2.mh-extra.com/html/iap/sf-1000/sf-1000_user-manual_3186097010.webp)
SF-1000 workbench
- 10 -
www.IAP-AirProducts.com
Compressed air supply connection
SUPPLY
INPUT
CONNECTOR OUTPUT
Technical Specifications
1.
Power supply - 24Vac ... 230Vac –
50/60Hz (on demand also 24 … 230 Vac/
dc)
2.
Max. power - 0.8A
3.
Absorbed power - 2mA (at rest)
4.
OPERATION time - 0-1 sec / 0-20 sec
(+/-3%)
5.
PAUSE time- 0-5 min / 0-40 min (+/-3%)
6.
Case - plastic self-estinguishable
material (UL94V0)
7.
Protection level - IP65
8.
Connections - DIN43650 B connesctor
9.
Preservation - 1 fuse = 1A quick acting
•
WARNING! Stop the filter unit and disconnect it from
power supply before filter change operation.
Installation and commissioning
1.
Check the delivery for completeness.
2.
Place the table at the destination and level.
3.
Mount self-supporting arm or connect to inlet ducting.
4.
Install cartridges and connect compressed air supply:
5.
Connect the device to the compressed air supply system. The compressed air must be clean and free of oil.
6.
Connect the device to the electrical system.
7.
The I / O control, boot (depending on the version of the timer should run periodically purge filter cartridges).
8.
Start the fan suction START / STOP button.