![iAIRE SHMSPZ-09 Скачать руководство пользователя страница 65](http://html2.mh-extra.com/html/iaire/shmspz-09/shmspz-09_manual_4935274065.webp)
iAIRE, LLC
65
SHVAC
Residential Mini-Split and Mounting Kit I/O/M
Floor and Roof Assembly Instructions
1. Assemble frame components together without solar box. See Exploded views for hardware.
a. Mount Top Cross Brace at least low enough along the Vertical Support to allow the Any Angle Bracket to
rotate.
b. Mount Bottom Cross Brace either well above or well below the Horizontal Support. Positioning is
determined by angle of Solar Box.
c. Note: Larger (10- and 15-Ton) frames have an additional Cross Brace.
d. Note: Larger (15-Ton) frames have an additional Horizontal Support.
2.Measure desired angle for Solar Box and fix Horizontal Supports in approximate position.
This can be adjusted after Solar Box mounting to ensure desired angle.
3. Mount frame to wall with lag bolts (not included) through the Cross Braces. For floor or roof mounting see
next page.
4. Mount Solar Box (pipe pop-outs on top) with edge of strut channels touching to form a solid triangle.
Tighten strut channel nuts once desired position is obtained.
5. Brace and secure piping to unistrut to plumb into the condensing unit. Be sure to follow line length
requirements for determining how far away the Solar Box can be mounted.
6. Insulate any exposed copper piping.
To mount Solar Box to a floor or roof, lay the frame with the cross braces on the bottom facing downward.
Assembly of components are exactly the same as the wall mounting configuration; see previous page for
detailed instructions.
To mount Solar Box to a floor or roof, lay the frame with the cross braces on the bottom facing
downward. Assembly of components are exactly the same as the wall mounting configuration;
see previous page for detailed instructions.
Wall Mounted
Floor Mounted
Roof Mounted
Floor and Roof Assembly Instructions