SW-4000T-MCL User Manual (2.0)
Main Functions
- 49 -
Variable Line Rate
Related Setting Items:
You can set the line rate to 1L or more.
This function can be used to match the scanning speed of the camera to the feeding speed of the
object or to lengthen the accumulation time to increase sensitivity.
l
Variable Range: 66 Hz to 67.7 kHz* (14.77 μs to 15.15 ms*)
l
Variable Unit: 0.1 Hz
l
Supported Operation Modes:
Exposure Mode = OFF / TriggerMode = Off
ExposureMode = Timed / TriggerMode = Off
Notes:
l
If AcquisitionLineRateOption is mode2(Default), the maximum line rate is limited to
56.338kHz.
l
You can also save the setting, and have it applied whenever the power is subsequently
turned on, but this requires addition operations.
l
Switching and settings storage for this function is performed via serial communication.
l
The black level will change depending on the line rate, so be sure to readjust the black
level after changing the line rate or trigger period.