background image

   

 

SCON 

First Step Guide   

Sixth Edition 

 

Thank you for purchasing our product. 
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to   
this First Step Guide to ensure correct use. 
This Instruction Manual is original. 
 
 
 
 
 

  Using or copying all or part of this Instruction Manual without permission is prohibited. 

 The company names, names of products and trademarks of each company shown in the sentences are registered 

trademarks.

 

 

Product Check 

This product is comprised of the following parts if it is of standard configuration. 
If you find any fault in the contained model or any missing parts, contact us or our distributor. 
1. Parts 

No. Part 

Name 

Model 

Reference 

1 Controller 

Main 

Body 

Refer to “How to read the model plate”, “How to read the model”   

Accessories 

I/O Flat Cable 

CB-PAC-PIO*** 

*** shows the cable 

length 

Service Connector for Pulse 

Train Control 

Plug : 10114-3000PE, Shell : 10314-52F0 (Supplier : 3M) 

 

System I/O Plug 

FMC1.5/4-ST-3.5 

(Supplier : Phoenix Contact) 

Power Supply Plug for Brake  MC1.5/2-ST-3.5 

(Supplier : Phoenix Contact) 

Applicable Cable Size 

0.5mm

2

 

(AWG20) 

AC Power Supply plug 

MSTB2.5/6-STF-5.08 

(Supplier : Phoenix Contact) 

Applicable Cable Size 

2.0mm

2

 

(AWG14) 

7 Absolute 

Battery 

AB-5 

Enclosed 

in 

Absolute 

Type 

First Step Guide 

 

 

Instruction Manual (CD/DVD)   

 

10 Safety 

Guide 

 

 

2. Teaching Tool (to be purchased separately) 
A teaching tool such as PC software is necessary when performing the setup for position setting, parameter 
setting, etc. that can only be done on the teaching tool. 
Please prepare either of the following teaching tools such as PC software. 

No. Part 

Name 

Model 

PC Software 

(RCS232C converter adapter and external equipment communication cable are included) 

RCM-101-MW 

PC Software 

(USB converter adapter, USB cable and external equipment communication cable are included) 

RCM-101-USB 

3 Touch 

Panel 

Teaching 

CON-PT 

Touch Panel Teaching (Dead-man Switch is included) 

CON-PD 

Touch Panel Teaching (Dead-man Switch and TP Adapter (RCB-LB-TG) are included) 

CON-PG 

6 Teaching 

Pendant 

CON-T 

Teaching Pendant (Dead-man Switch and TP Adapter (RCB-LB-TG) are included) 

CON-TG 

8 Simplified 

Teaching 

Pendant 

RCM-E 

9 Data 

Setter 

RCM-P 

10  Touch Panel Indicator (Specified only for SCON-C) 

RCM-PM-01 

3. Instruction manuals related to this product, which are contained in the Instruction manual (CD/DVD). 

No. Name 

Manual 

No. 

SCON Controller Instruction Manual 

ME0161 

SCON-CA Controller Instruction Manual 

ME0243 

PC Software 

RCM-101-MW/ RCM-101-USB Instruction Manual 

ME0155 

Touch Panel Teaching 

CON-PT/PD/PG Instruction Manual 

ME0227 

Teaching Pendant 

CON-T/TG Instruction Manual 

ME0178 

Simplified Teaching Pendant  RCM-E Instruction Manual 

ME0174 

Data Setter 

RCM-P Instruction Manual 

ME0175 

Touch Panel Indicator 

RCM-PM-01 (Specified only for SCON-C) 

ME0182 

4. How to read the model plate 

 
 

 
5. How to read controller model 

 

 
 
 
 
 
 
 
 

 

Basic Specifications 

List of Specifications 

Item 

Less than 400W 

400W or more 

Corresponding Motor Capacity 

20W to 399W 

400W to 750W 

Power-supply Voltage 

Single-Phase 100 to 115V AC 

(Power fluctuation within 

±

10%) 

Single-Phase 200 to 230V AC 

(Power fluctuation within 

±

10%) 

Single-Phase 200 to 230V AC   

(Power fluctuation within 

±

10%) 

Power-supply Voltage 100V AC

 

Rush 

Current

*1

 

Power-supply Voltage 200V AC

20A (Controller side), 70A (Drive side) 

20A (Controller side), 80A (Drive side) 

Load Capacity 

Refer to Power Capacity and Heat Generation 

Leak Current

*2

 

3.0mA    Primary side when noise filter is connected to power supply line 

Heat Generation 

Refer to Power Capacity and Heat Generation 

Power Supply Frequency 

50/60Hz 

PIO Power Supply

*3

 24V 

DC

±

10% 

Power Supply for Electromagnetic Brake

(for actuator equipped with brake) 

24V DC

±

10%  1A (MAX.)  

(supplied from external equipment) 

SCON-C 

10ms (50Hz), 8ms (60Hz) 

Transient Power 

Cutoff Durability 

SCON-CA 20ms 

(50Hz), 16ms (60Hz) 

Motor Control System 

Sine Wave PWM Vector Current Control 

Corresponding Encoder 

Incremental Serial Encoder, Absolute Serial Encoder, ABZ (UVW) Parallel Encoder 

Actuator Cable Length 

MAX. 20m 

Serial Communication Interface 

RS485  : 1CH … based on Modbus Protocol RTU/ASCII 

Speed  : 9.6 to 230.4Kbps 

Control available with serial communication in the modes other than the pulse train 

PIO 

Specifications

Signal I/O dedicated for 24V DC (selected from NPN/PNP) … Input 16 ports max., 

output 16 ports max. 

External Interface 

Fieldbus 

Specification

DeviceNet/CC-Link/PROFIBUS/CompoNet/MECHATROLINK …Each dedicated controller

[Refer to each Fieldbus Instruction Manual] 

PIO MAX. 

10m 

RS485 

Total cable length 100m or less. 

Cable Length 

Fieldbus 

Refer to each Fieldbus specification 

Data Setting and Input 

PC Software, Touch Panel Teaching, Teaching Pendant 

SCON-C 

Saves position data and parameters to non-volatile memory   

(Limitation in number of writing 100,000 times) 

Data Retention 

Memory 

SCON-CA 

Saves position data and parameters to non-volatile memory   

(There is no limitation in number of writing) 

Operation Mode 

Positioner Mode/Pulse Train Control Mode   

(selected by Pulse Train Mode Changeover Switch on Front Panel) 

Number of Positions in Positioner 

Mode 

Standard 64 points, maximum 512 points (PIO Type), 768 points (only for SCON-CA Fieldbus Type)

(Note)  Number of positions differs depending on the selection in PIO pattern and fieldbus operation mode.

SCON-C 

Differential System (Line Driver System) : MAX. 500Kpps 

SCON-CA 

Differential System (Line Driver System) : MAX. 2.5Mpps 

Input 

Pulse 

Frequency  Common to C/CA Open Collector Type 

: 200Kpps max. (under condition AK-04 is used) 

Pulse Train 

Control 

Mode 

(Dedicated 

for PIO 

Specifications) 

Command Pulse 

Multiplying Factor 

(Electrical Gear : A/B) 

1/50 

A/B 

<

 50/1 

Setting Range of A and B (set to parameter) : 1 to 4096 

SCON-C 

Differential System (Line Driver System) : MAX. 500Kpps (Linear output available up to 109Kpps)

SCON-CA 

Differential System (Line Driver System) : MAX. 2.5Mpps 

Feedback Pulse 

(Dedicated for PIO 

Specifications) 

Common to C/CA Open Collector Type 

: MAX. 500Kpps (under condition JM-08 is used) 

LED Display   

(mounted on Front Panel) 

PWR (green)  : Controller in normal condition,  SV (green) : Servo on, 

ALM (orange) : Alarm generated, 

EMG (red)  : Emergency Stop 

Electromagnetic Brake Compulsory Release 

Switch (mounted on Front Panel) 

Switching NOM (standard)/BK RLS (compulsory release) 

Insulation Resistance 

500V DC    100M

Ω

 or more 

Insulation Strength 

1,500V AC for 1 min.    (Note) Withstand voltage of force control loadcell is 50V DC 

Surrounding air temperature 0 to 40

°

Surrounding humidity 

85%RH or less (non-condensing) 

Surrounding environment 

[Refer to Installation Environment] 

Surrounding storage temperature -10 to 65

°

Surrounding storage humidity  90%RH or less (non-condensing) 

Environment 

Vibration Durability 

XYZ Each direction  10 to 57Hz Pulsating amplitude 0.035mm (continuous)    0.075mm (intermittent)
 

57 to 150Hz 4.9m/s

2

 (continuous)  9.8m/s

2

 (intermittent) 

Protection Class 

IP20   

Weight 

Approx. 800g 

Approx. 1100g 

Cooling Method 

Natural air-cooling 

Forced Air Cooling 

External Dimensions 

58W 

×

 194H 

×

 121D [mm] 

72W 

×

 194H 

×

 121D [mm] 

 

*1  In-rush current will flow for approximately 20msec after the power is turned on (at 40

°

C). 

Note that the value of in-rush current differs depending on the impedance of the power supply line. 

*2  Leak current varies depending on the capacity of connected motor, cable length and the surrounding environment. Measure the 

leak current at the point where a ground fault circuit interrupter is to be installed when leakage protection is conducted. 
A ground fault circuit interrupter needs to be selected carefully considering the purposes of prevention of fire and 
protection of human. 
Use the harmonic type (for inverter) for the ground fault circuit interrupter. 

*3  It is not necessary to supply power to PIO when operating with using ROBONET, Gateway Unit or SIO Converter 

without using PIO. In this case, set the parameter No. 74 (PIO Power Supply Monitor) to “1” (Invalid). It will generate 
the error code No. 0CF (I/O 24V Power Supply Error) if the setting is not done. 

Power Capacity and Heat Generation 

Rated Power Capacity 

=

 Motor Power Capacity 

+

 Control Power Capacity 

Peek Max. Power Capacity 

=

 Peek Max. Motor Power Capacity 

+

 Control Power Capacity 

Actuator Motor Type 

Motor Power 

Capacity 

[VA] 

Peek Max. Motor 

Power Capacity 

[VA] 

Control Power 

Capacity 

[VA] 

Rated Power 

Capacity 

[VA] 

Peek Max. Power 

Capacity [VA] 

Heat Generation

[W] 

20 26 

78 

74 

126 

30 

30D (Excluding RS) 

46 

138 

94 

186 

31 

30R (for RS) 

138 

414 

186 

462 

33 

60 138 

414 

186 

462 

33 

60 (RCS3-CTZ5) 

197 

591 

245 

639 

32 

100 234 

702 

282 

750 

35 

100S (LSA) 

283 

851 

331 

899 

36 

150 328 

984 

376 

1032 

37 

200 421 

1263 

469 

1311 

38 

200S 

(LSA excluding LSA-N15H) 

486 1458 

534 1506  38 

200S 

(LSA-N15H) 

773 2319 

821 2367  56 

300S 

(LSA) 662 1986 

710 2034  40 

400 

920 2760 

968 2808  45 

400 

(RCS3-CT8) 

1230 3690 

1278 3738  47 

600 1164 

2328 

1212 

2376 

56 

750 3042 

3090 

750S 

1521 

4563 

48 

1569 

4611 

58 

RS : Rotary Shaft      LSA : Linear Actuator 

Selection of Circuit Interrupter 

• 

3 times of the rated current flows to the controller during the acceleration/deceleration. Select an interrupter that does not trip 
with this value of current. If a trip occurs, select an interrupter that possesses the rated current of one grade higher. (Refer to 
the operation characteristics curves in the product catalog.) 

• 

Select an interrupter that does not trip with the in-rush current. (Refer to the operation characteristics curves in the product 
catalog.) 

• 

Consider the current that enables to cutoff the current even when a short circuit current is flown for the rated cutoff current. 
Rated Interrupting Current 

>

 Short Circuit Current 

=

 Primary Power Capacity / Power Voltage 

Consider margin for the rated current on the circuit breaker. 

Rated Current for Circuit Interrupter 

>

 (Rated Motor Power Capacity [VA] 

+

 Control Power Capacity [VA]) / 

AC Input Voltage 

×

 Safety Margin (reference 1.2 to 1.4 times) 

 

External Dimensions 

Less than 400W 

400W or more 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Regenerative Resistor Unit (Option) : REU-1, REU-2 

This is a unit that converts the regenerative current to heat when the motor decelerates. 
[Specification]

 

[Appearance] 

Item Specification 

Body Size 

W34mm 

×

 H195mm 

×

 D126mm

Body Weight 

0.9kg 

Internal Regenerative Resistor 

235

Ω

  80W 

REU-1 

(2nd unit or later) 

Controller Connection Cable 

(Model Code CB-ST-REU010) 1m

Accessories 

REU-2 

(First Unit) 

Controller Connection Cable 

(Model Code CB-SC-REU010) 1m

[Reference Connectable Quantity] 

Motor Wattage 

Horizontal Mount/Vertical Mount 

Connectable Number of 

Regenerative Resistor Units 

To 100W

(Note 3)

 

Not Required 

101 to 400W 

401 to 750W 

(Note 1) This is a reference for the case when the actuator is ran forward and backward on 1,000mm stroke with the 

operation duty 50% under the rated acceleration/deceleration speed and rated load. 

(Note 2) It is necessary to have the regenerative resistor listed above when the operation duty is above 50%. 

The maximum quantity of the external regenerative resistor units that can be connected is as stated below:

 

 2 units for less than 400W 

 4 units for 400W or more 

(Note 3) 

It is necessary to have one unit for LSA/LSAS-N10S Type. 

 

Brake Box (Option) : RCB-110-RA13-0 

This is applied on NS Actuator and RCS-RA13R with brake. 
1 unit of Brake Box possesses brakes for 2 shafts.

 

[Specification]

 

[Appearance]

 

Item Specification 

Body Size 

W162 

×

 H94 

×

 D65.5mm 

Power Voltage and Current 

24V DC

±

10%  1A 

Connection Cable 

Encoder Cable 

(Model Code CB-RCS2-PLA010) 1m

[24V Power Supply Connector] 

Connector on 

Cable Side 

(Enclosed in 

standard package) 

MC1.5/2-STF-3.5 (Phoenix Contact) 

Applicable Cable 

AWG28 to 16 

Pin No.  Signal 

Explanation 

0V 

Power Supply Grounding for 

Brake Excitation 

Terminal 

Assignment 

24VIN 

For Brake Excitation and   

24V Power Supply 

[Connectors 1 and 2 for external brake release switch connection] 

Connected 

Equipment 

Brake Release Switch 

Connector on 

Cable Side 

(Please prepare 

separately) 

XAP-02V-1 

(Contact BXA-001T-P0.6) (JST) 

Switch Rating 

30V DC      Minimum Current 1.5mA 

Pin No.  Signal 

Explanation 

BKMRL  Brake Release Switch Input

Terminal 

Assignment 

2 COM 

Power Supply Output for Brake 

Release Switch Input 

(Note)  Short circuit of pin No. 1 and 2 of this connector releases the brake compulsorily. 

 

Same as the brake release switch on SCON main unit, it is possible to release the brake. 

Do not keep the compulsory release condition while in automatic operation. 

Serial number

Model

SCON-CA-60A-NP-2-1

MODEL

SERIAL No. 

800056144   L11

MADE IN JAPAN

S C O N - C A - 2 0   I   H A - N P - 2 - 0 - C T 4 - * *  

<Series> 

 

<Type> 

C : 

Standard 

Type 

CA : 

High 

Performance 

Type 

 

<Actuator Characteristics> 

[Motor Type] 

20 : 

20W 

 

200 : 

200W 

30D  :  30W (Excluding RS)    200S  :  200W (LSA) 

30R  :  30W (for RS) 

  300S  :  300W (LSA) 

60 : 

60W 

 

400 : 

400W 

100 : 

100W 

 

600 : 

600W 

100S : 100W (LSA) 

 750  : 750W 

150  : 150W 

 750S : Equipped with 

  

 

 

 Loadcell 

  

 

 

 RCS2-RA13R 

<Encoder Type> 

I : Incremental 

A : Absolute 

<Option> 

No Indication : Standard Type 

HA : High Acceleration/Deceleration Type 

 

<Identification for IAI use only> 
* There is no identification in some cases. 

 
<ROBO Cylinder High-Speed Type Connection> 

 

<Power-supply Voltage> 

1 : Single-Phase 100V AC 

2 : Single-Phase 200V AC 

 

<I/O Cable Length> 

0  :  Equipped with no cable 

2 : 2m 

3 : 3m (Standard) 

5 : 5m 

 

<I/O Type> 

NP  : NPN Specification (Sink Type) (Standard) 

PN  : PNP Specification (Source Type) 

DV  : DeviceNet Connection Type 

CC  : CC-Link Connection Type 

PR  : PROFIBUS Connection Type 

CN  : CompoNet Connection Type

(Note)

 

ML  : MECHATROLINK Connection Type

(Note) 

EC  : EtherCAT Connection Type

(Note) 

EP : EtherNet/IP Connection Type

(Note)

 

(Note) Specified only for SCON-CA 

121

min80

58

29

φ

4.2

184

194

(200.5)

5

4.2

Absolute Battery
(for Absolute Encoder Type)

72

43

φ

4.2

4.2

5

184

194

(200.5)

Absolute Battery
(for Absolute Encoder Type)

Side View (in common)

φ

5

34

195

186

175

126

min
100

16.6

5

94

70

12

5

5

152
162

142

4-

φ

5

LS Input Connector

Encoder Input Connector

Encoder Output Connector

Primary 

Shaft

min100

12

Connector 2 for 
External Brake Release 
Switch Connection 
(for the primary shaft)

Power Supply 
Input Connector

POWER ON LED 
(turns in green while on)

Connector 2 for 
External Brake Release 
Switch Connection 
(for the secondary shaft)

Secondary 

Shaft

Warning :  Operation of this equipment requires detailed installation and operation instructions which are 

provided on the DVD Manual included in the box this device was packaged in. It should be retained 

with this device at all times. 

 

A hardcopy of the Manual can be requested by contacting your nearest IAI Sales Office listed at   

the back cover of the Instruction Manual or on the First Step Guide. 

Содержание scon

Страница 1: ...er the power is turned on at 40 C Note that the value of in rush current differs depending on the impedance of the power supply line 2 Leak current varies depending on the capacity of connected motor cable length and the surrounding environment Measure the leak current at the point where a ground fault circuit interrupter is to be installed when leakage protection is conducted A ground fault circu...

Страница 2: ... 2 SK Surge Killer It is recommended to attach it to improve noise immunity 3 NF Noise Filter Make sure to install it It is recommended to have it installed within 0 3m of the cable length from SCON Parts Name Supplier Model CLF Clamp Filter TDK ZCAT3035 1330 SK Surge Protector Okaya ELECTRIC CO LTD R A V 781BWZ 2A SOSHIN ELECTRIC CO LTD NF2010A UP NF Noise Filter DENSEI LAMBDA MC1210 Wiring for E...

Страница 3: ...y alarm overload alarm or message level alarm is occurred Signal Assignment for Each Mode The signal assignment of I O flat cable by the PIO pattern is as shown below Follow the following table to connect the external equipment such as PLC Corresponding Type All Types Selection in Parameter No 25 PIO Pattern 0 1 2 3 Category PIO Functions Positioning mode Teaching mode 256 point mode 512 point mod...

Страница 4: ... the alarm to have the right treatment CAUTION Please perform this process with the actuator away from the mechanical end or interfering subjects as much as possible Put the actuator away if it interferes with surroundings It may generate an alarm if the actuator hit the mechanical end or interfering subjects when the servo is turned on The slider may get slightly dropped by self weight if servo o...

Отзывы: