![IAI ROBO Cylinder RCS2 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/iai/robo-cylinder-rcs2/robo-cylinder-rcs2_operating-manual_604041027.webp)
17
Tapped hole
Reamed hole
7.4
Installing the load to the Slider
7.4.1
Using the Slider
Tapped holes are provided on the slider for installing the load. The method of clamping varies
according to how to mount the main body.
In case of moving actuator instead of slider, use the same tapped holes on the slider.
Please use two reamed holes on the slider when repeatability of mounting and dismounting is required.
When fine adjustment of the squareness is necessary, use only one reamed hole to allow adjustment.
Sizes and depths of tapped holes and reamed holes on slider
Model
Tap size
Depth of thread
A
B
C
Reamed hole
SA4
M3
7 mm
24 mm
16 mm
20 mm
3 H7, depth 5 mm
SA5
M4
9 mm
30 mm
19 mm
26 mm
4
H7, depth 6 mm
SA6
M5
9 mm
50 mm
32 mm
31 mm
5 H7, depth 6 mm
SA7
M5
10 mm
50 mm
32 mm
39 mm
5 H7, depth 10 mm
SS7
M5
10 mm
50 mm
32 mm
32 mm
5 H7, depth 10 mm
SS8
M8
10 mm
75 mm
45 mm
45 mm
8
H7, depth 10 mm
Caution:
When installing the load, do not let adhesives, paints or other viscous substances