
53
1. S
pecification
s
Che
c
k
[4] RA8C and RA8R Motor Type 60P
Current Limit Value
Lead 5 [N]
Lead 10 [N]
Lead 20 [N]
20% 667 333 167
30% 1000 500 250
40% 1333 667 333
50% 1667 833 417
60% 2000 1000 500
Caution: (1) The relation of the current limit and the pressing force is a reference when
assuming the speed is 10mm/s.
(2) There is a little variance in the actual pressing force. The variance of the
pressing force becomes large when the current limit value is low.
(3) Use the product within the range in the graph for the current limit value.
Pressing force will not be stable if used below 20%. There is even a case
that it would not operate. An operation cannot be made also when it is
beyond 60%. Doing so may cause degradation in the motor coil insulation
by heat radiation, which results in shortening the product life.
(4) For CON-system controllers such as PCON, when the approach speed to
the pressing start position (setting in the position table) is 10mm/s or less,
pressing will be performed with the approach speed In such a case also
the pressing force will be unstable. In such cases, check in advance that
the actuator can be used with no problem before omit using.
For SEL-system controllers, such as MSEL, press at the speed set by
PAPR instruction, regardless of the approach speed up to the pressing
start position.
Current Limit Value [%]
Lead 20
Lead 10
Lead 5
Pre
s
s
ing Forc
e
[N]
RA8C/R Current Limit Value and Pressing Force
Содержание ROBO Cylinder RCP6
Страница 2: ......
Страница 8: ......
Страница 79: ...74 2 Installation RA8 Stroke 185 5 Maximum Stroke 70 5 Minimum 15...
Страница 146: ......