Attachment
Refer to the Instruction Manual (DVD) for the attachments of the actuator and loads.
[Precautions for Attachments]
No.
Item
Precautions
1
Installation
•
Installing the slider type in the horizontally oriented wall mount or ceiling
mount may cause the stainless steel sheet to be loosened or be off the
right position. Continued use of the actuator with this condition may
result in the breakage of the stainless steel sheet. Adjust the sheet
tension accordingly in the regular inspection.
(Refer to the maintenance section on the Instruction Manual for the
procedure of stainless steel sheet tension adjustment.)
•
Avoid using the actuator with no brake in the vertical orientation.
2
Attachment Surface
•
The base has to have a structure with sufficient rigidity to prevent
oscillation.
•
The side and the bottom surfaces of the base of the actuator are the
datum for the slider drive. If accuracy for its run is required, use these
surfaces as a datum of the installation.
Datum Surface
Datum Surface
•
The actuator mounting surface and other surfaces that are used as a
datum should be flat enough with an accuracy of machining or
equivalent treatment, and the flatness of the mounting surface needs to
be 0.05mm/m or less.
•
Secure the space where maintenance work can be performed.
3
Bolt to be used
•
For the bolts to be used, a high-tensile bolt complying with ISO-10.9 or
more is recommended.
•
Use stainless steel screws for Dustproof/splash proof type RCP5W.
•
If using the tapped holes, use screws with the thread length dimension
being less than the effective depth of the holes.
•
In case the tapped hole is a through hole, be careful so the screw tip
does not exceed the surface of the tapped hole.
•
For the actuator mounting, use a bolt with the dimension of its effective
mating length to the tapped hole is as stated below.
If tapped hole on steel
→
thread length same as nominal diameter
If tapped hole on aluminum
→
thread length 1.8 times longer than
nominal diameter
However, when utilizing the tapped hole actuator attach on,
RCP5-RA4C/4R is 6mm or less,
RCP5-RA8C/8R is 12mm or less,
RCP5-RA10C/10R is 15mm or less,
RCP5W-RA6C is 6mm or less,
RCP5W-RA7C is 7.5mm or less.
RCP5W-RA8C is 8.5mm or less,
RCP5W-RA10C is 10mm or less.
4
Tightening Torque
•
Please follow the specification values stated in the Instruction Manual
(DVD) for the tightening torque.
Failure to do so may cause an operation problem.
5
Load Moment and
Overhung length
•
Please follow the specification values stated in the Instruction Manual
(DVD) for the load moment and the overhung length of the slider type.
Failure to do so may cause abnormal vibration or noise, and also may
remarkably shorten the product life.
6
Rod Tip Allowable
Static Load, Load
Offset Distance
•
Follow the specific values described in the instruction manual (DVD) for
the rod tip dynamic allowable load and the load offset distance for the
rod type. Failure to do so may cause abnormal vibration or noise, and
also may remarkably shorten the product life.
7
Stainless steel sheet
•
Please do not hold the stainless steel sheet directly with hands. Please,
also, be careful not to make a dent on the stainless steel sheet.
Stainless sheet is easy to get dented because it is thin. Using it with a
dent on may cause a breakage.
•
If there is dust or metal contamination attached on the stainless steel
sheet, please wipe it off the sheet surface. Operation with the stainless
sheet that has foreign matters on its surface may cause problems such
as sheet damage, waviness, etc. inside the slider.
•
Please do not operate the unit in the ambient with dust or metal
contamination.
For the controller, only the dedicated controller manufactured by our company can be used.
For the connection between the actuator and controller, use the attached dedicated connection
cable.
[Prohibited Items in the Cable Processing]
•
Do not pull or bend forcibly the cable so as not to give any extra load or tension to the
cable.
•
Do not process the cable for extension or shortening by means of cutting out,
combination or connecting with another cable.
•
Do not bend the cable in the area from the connector tip to 150mm on the both ends.
Standard cable : CB-CAN-MPA
□□□
, CB-CFA3-MPA
□□□
Robot cable : CB-CAN-MPA
□□□
-RB, CB-CFA3-MPA
□□□
-RB
150mm
150mm
•
Do not let the cable flex at a single
point.
•
Do not let the cable bend, kink or twist.
•
Do not pull the cable with a strong
force.
•
Do not let the cable receive a turning force
at a single point.
•
Do not pinch, drop a heavy object
onto or cut the cable.
•
When fixing the cable, provide a moderate
slack and do not tension it too tight.
•
Separate the I/O line,
communication line and power line
from each other.
Do not store in the same duct.
Follow the instructions below when using a
cable track.
•
If there is an indication to the cable for the
space factor in a cable track, refer to the
wiring instruction given by the supplier
when storing the cable in the cable track.
•
Avoid the cables to get twined or twisted
in the cable track, and also to have the
cables move freely and do not tie them
up. (Avoid tension being applied when the
cables are bent.)
Do not pile up cables. It may cause faster
abrasion of the sheaths or cable
breakage..
Note:
•
When the cable is connected or disconnected, make sure to turn off the power to the
controller. When the cable is connected or disconnected with the controller power turned
ON, it might cause a malfunction of the actuator and result in a serious injury or damage
to the machinery.
•
When the connector connection is not correct, it would be dangerous because of a
malfunction of the actuator. Make sure to confirm that the connector is connected
correctly.
Head Office: 577-1 Obane Shimizu-KU Shizuoka City Shizuoka 424-0103, Japan
TEL +81-54-364-5105 FAX +81-54-364-2589
website: www.iai-robot.co.jp/
Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany
TEL 06196-88950 FAX 06196-889524
SHANGHAI JIAHUA BUSINESS CENTER A8-303, 808, Hongqiao Rd. Shanghai 200030, China
TEL 021-6448-4753 FAX 021-6448-3992
website: www.iai-robot.com
Technical Support available in USA, Europe and China
Head Office: 2690 W. 237th Street, Torrance, CA 90505
TEL (310) 891-6015 FAX (310) 891-0815
Chicago Office: 110 East State Parkway, Schaumburg, IL 60173
TEL(847) 908-1400 FAX (847) 908-1399
TEL (678) 354-9470 FAX (678) 354-9471
website: www.intelligentactuator.com
Atlanta Office: 1220 Kennestone Circle, Suite 108, Marietta, GA 30066
825 PhairojKijja Tower 12th Floor, Bangna-Trad RD., Bangna, Bangna, Bangkok 10260, Thailand
TEL +66-2-361-4458 FAX +66-2-361-4456
Steel Strap
(Piano Wire)
Tie them up softly.
Do not use spiral tube in any
position where cables are bent
frequently.
Power Line
Duct
I/O Line
(Flat Cable, etc.)
Manual No.: ME3736-7B