Driver Unit
Gateway Unit
Terminal Unit
Extension
Unit
Fan Unit
Model
Model Plate (Large)
Refer to “External Dimensions”
for the attached position.
Serial Number
-GW/GWG,
-GW-TR
Gateway Unit, Terminal Unit
First Step Guide Second Edition
Thank you for purchasing our product.
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the
product in addition to this First Step Guide to ensure correct use.
This Instruction Manual is original.
•
Using or copying all or part of this Instruction Manual without permission is prohibited.
•
The company names, names of products and trademarks of each company shown in the sentences
are registered trademarks.
RCON System is constructed not only with the Gateway Unit (RCON-GW/GWG) and Terminal Unit (RCON-
GW-TR) that are explained in this manual, but also with Driver Unit (RCON-PC/PCF/AC/DC/SC), Power
Supply Unit (RCON-PS2), Simple Absolute Unit (RCON-ABU), Fan Unit (RCON-FU), Extension Unit
(RCON-EXT) and SCON Controller (SCON-CB-*-RC) to connect to the extension unit. Please refer to First
Step Guide and Instruction Manual (DVD) of each device for additional instruction related to that device.
Gateway Unit is a communication unit to be connected to the field network and must be located on the left
end of the RCON System.
The terminal unit is a terminal resistor that should be allocated at the right end of RCON System.
This product is comprised of the following parts if it is of standard configuration.
If you find any fault in the contained model or any missing parts, contact us or our distributor.
1. Parts
No.
Part Name
Model
Number
Remarks
1 RCON Gateway Unit
Refer to “How to read the model
plate”, “How to read the model code”
1
Accessories
2 Terminal Unit
(Terminal Resistance) RCON-GW-TR
1
Select-TRN (with no terminal
unit) in the option if it is not
necessary
3 Fan Unit
RCON-FU
*1
*1 Indicate number of units in
the option
4 System I/O Connector DFMC1.5/5-ST-3.5
(Manufactured by PHOENIX CONTACT)
1
Recommended Cable Size
0.5 to 1.25mm
2
(AWG20 to 16)
5 Dummy Plug
DP-5
1
For the safety category
compliant type
6 CC-Link
Connector
(Enclosed for CC-Link Type)
MSTB2.5/5-STF-5.08 AU
(Manufactured by PHOENIX CONTACT)
1
Terminal Resistance (130
Ω
/110
Ω
)
enclosed one unit each
Recommended Cable Size
0.3mm
2
(AWG22)
7 DeviceNet
Connector
(Enclosed for DeviceNet Type)
MSTB2.5/5-STF-5.08 AU M
(Manufactured by PHOENIX CONTACT)
1
Recommended Cable Size
0.3mm
2
(AWG22)
8 First Step Guide
ME0382
1
This Manual
9 Instruction Manual (DVD)
1
10 Safety Guide
M0194
1
(4) System I/O Connector
(5) Dummy Plug
(6) CC-Link Connector
(7) DeviceNet Connector
2. Teaching Tool (Please purchase separately)
A teaching tool such as PC software is necessary when performing the setup for position setting, parameter
setting, etc. that can only be done on the teaching tool. Please prepare either of the following teaching tools.
No.
Part Name
Model
1 PC Software (Includes USB Exchange A USB Cable + Peripheral Communication Cable)
RCM-101-USB
2 Touch Panel Teaching Pendant TB-02 (Standard/ Dead Man’s Switch Mounted)
TB-02/TB-02D
3 Touch Panel Teaching Pendant TB-03
TB-03
3. Instruction manuals related to this product, which are contained in the instruction manual (DVD).
No.
Name
Manual No.
1 RCON System Instruction Manual
ME0384
2 SCON-CB/CGB/LC/LCG Controller Instruction Manual
ME0340
3 PC Software RCM-101-MW/RCM-101-USB Instruction Manual
ME0155
4 Touch Panel Teaching Pendant TB-02 Applicable for Position Controller Instruction
Manual
ME0355
5 Touch Panel Teaching Pendant TB-03 Wired Link Applicable for Position Controller
Instruction Manual
ME0376
4. How to read the model plate
Mark
Explanation of Mark
Use IAI specified cables only.
5. How to read the model code
1. Specifications of Power Supply
Item
Specification
Power Input Voltage Range
24V DC ±10%
Supply Current
Refer to “Current Amperage” in RCON Driver Unit First Step Guide (ME0383)
Current Amperage
Refer to “Current Amperage” in RCON Driver Unit First Step Guide (ME0383)
In-Rush Current
Refer to “Current Amperage” in RCON Driver Unit First Step Guide (ME0383)
Instantaneous Power Outage Endurance By 24V power supply
Protection Function against Electric Shock Class
Ⅲ
2. Specifications of Control Part
Item
Specification
Number of Controlled Axes
1 to 16 axes
Data Memory System
Position data and parameters are saved in the nonvolatile memory.
(There is no limitation in number of writing)
SIO Interface (T. P. Connector)
Communication System: RS485, Baud Rate: 9.6/19.2/38.4/57.6/115.2/230.4kbps
SIO Interface (USB Connector)
Communication System: USB, Baud Rate: 12Mbps
PIO Interface
None
Conformed Extension I/O Interface
(Field Network Interface)
CC-Link, CC-Link IE Field, DeviceNet, EtherCAT, EtherNet/IP, PROFIBUS-DP,
PROFINET IO
Pulse Train Type
Unavailable to Control
Brake Output Voltage
24V DC ±10%
Calendar Feature
Maintained Duration: Approx. 10 days, Charge Time: Approx. 100 hours
Applied Safety Category
B (Safety category applicable type is capable to achieve 4 with external circuit)
Driver Source Cutoff System
Drive source cutoff with semiconductor (Power MOSFET)
Stop Input
Break Contact Input
Stop Action
Turning servo OFF + Drive source cutoff
Enable Input
None
T. P. Enable Input
Available
Enable Action
Turning servo OFF
Protective functions
Overcurrent, temperature error, encoder line breakage and overload
Preventive / Predictive Maintenance Feature Electrolytic capacitor capacity dropdown and Fan revolution dropdown
LED Display
Refer to section in “Troubleshooting (LED Display)”
Brake Compulsory Release Feature
Brake release switch equipped on driver unit
Jog
Jog switch equipped on driver unit
Oversea Certifications
CE Marking, UL Standard
3. Environmental Specifications
Item
Specification
Envi
ro
nm
en
t
Environment of Use
Pollution Degree 2
Surrounding Air Temperature
0 to 55
°
C
Surrounding Humidity
85% RH or less (non-condensing)
Peripheral Ambience of Use
Refer to “Installation Environment”
Surrounding Storage Temperature
-20 to 70
°
C
Vibration Durability
Frequency 10 to 57Hz/Swing width: 0.075mm
Frequency 57 to 150Hz/Acceleration: 9.8m/s
2
XYZ Each direction Sweep time: 10min. Number of sweep: 10times
Protection Class
IP20
Altitude
1000m
Cooling Method
Natural air-cooling
Dielectric Withstanding Voltage
Between power supply terminal and FG 500V DC 10M
Ω
or more
Front
Top
Product Check
Basic Specifications
Names for Each Part
Warning: Operation of this equipment requires detailed installation and operation instructions
which are provided on the DVD Manual included in the box this device was
packaged in. It should be retained with this device at all times.
A copy of the DVD Manual can be requested by contacting your nearest IAI Sales
Office listed at the back cover of the Instruction Manual or on the First Step Guide.
2A
Serial Number
Model Code (Partially)
Model Plate (small)
It is attached on the
bottom of the panel
front face.
R C O N
-
G W G
-
P R T
-
F U 4
-
* *
<
Series >
<Type>
GW : Standard Type
GWG : Safety Category Compliant Type
<Option>
ET : Equipped with Ethernet
FU* : Equipped with Fan Unit
(* : Indicate number of units to mount from
1 to 8 after FU)
TRN : With No Terminal Unit
<I/OType>
CC : CC-Link Connection Type
CIE : CC-Link IE Field Connection Type
DV : DeviceNet Connection Type
EC : EtherCAT Connection Type
EP : EtherNet/IP Connection Type
PR : PROFIBUS-DP Type
PRT : PROFINET IO Connection Type
<Identification for IAI use only>
* There is no identification in
some cases
Field Network
Connector
SYS LED
STATUS 1 LED
STATUS 0 LED
C ERR LED
MODE LED
STOP LED
T RUN LED
Ethernet Connector
T.P. (SIO) Connector
System I/O Connector
Motor Power Supply
Connector
Control Power Supply
Connector
AUTO/MANU Switch
USB Connector