![IAI PSA-24 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/iai/psa-24/psa-24_instruction-manual_604103056.webp)
6.1 Before Considering Failure
6-1
6.
B
ef
or
e
C
ons
ider
ing F
ai
lu
re
6.1 Before Considering Failure
Content
Countermeasures
No output voltage
• Is the specified input voltage connected?
• Is there a short circuit or ground fault in the output circuit?
• Has the power supply unit been rebooted immediately after the
overvoltage circuit / overheat protection circuit activated?
• Is the power on at the same time during parallel operation?
• Is the ambient temperature high?
• Is there an overload?
Low output voltage
• Is there an overload?