IAI PSA-24 Скачать руководство пользователя страница 2

External Dimensions 

 

PSA-24 

 
 
 
 
 

 

PSA-24L 

 
 
 
 
 
 
 
 
 
 
 

Name and Function of Each Part 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
[1]  Connector for FAN Connection 

It is the connector for fan connection when using at 330W for the continuous rated output. 

 
 
 
 
 
 
 
 
 
 

 
Connector Names on PCB side : DF11-4DP-2DS (24) (HIROSE ELECTRIC CO., LTD.) 

Pin Number Signal 

Description 

24V 

Fan Power Supply 

2 CONNECT 

Connection Recognition Signal 
(Connected : H / Unconnected : L) 

GND 

GND for Fan 

PULSE 

Fan Rotation Pulse 

 

[2]  Connector for Communication 

It is the connector to monitor the status data inside the power source by communication.

 

There are two inlets in order to enable communication with multiple power sources in 
multi-drop wiring.

 

It can be connected to either of the inlets because the differential signal 

on each inlet is short-circuited with each other inside. The connector on the cable is 
enclosed. 

 
 
 
 
 
 
 
 
 
 

 

Connector Names on PCB side : 0221-26-6615-06THT (DINKLE) 
Connector Names on Cable Side (Accessories) : 0221-2403 (DINKLE) 

Pin Number Signal 

Description 

SD+ 

Positive Side of RS485 Differential Signal 

SD- 

Negative Side of RS485 Differential Signal 

3 GND 

 

SD+ 

Positive Side of RS485 Differential Signal 

SD- 

Negative Side of RS485 Differential Signal 

6 GND 

 

*  There is no impact to the operation of the power source itself even if there is no 

communication connector connected. 

 
 

[3]  Address Switch for Communication

 

Set up the slave address assignment in communication for when connecting multiple 
power sources in multi-drop wiring and monitoring the status by communication. 

 
 
 
 
 
 
 
 
 
 

 

Switch Names : DRR7016C (NIDEC COPAL ELECTRONICS CORPORATION) 

Item Description 

Initial Setting 

“0” 

Range for 
Setting 

“0” to “F” 

 

[4] Fan Unit

 

Unit to connect when using at 330W for continuous rated output (PSA-24L) 

 

[5] FAN Alarm LED Lamp

 

 

[6]  Normal Operation LED Lamp

 

This power source is equipped with two types of LED lamps as shown below. 

 
 
 
 
 
 
 
 
 
 

 

Description on 

Panel 

Display 

Color 

Status Description 

FAN Orange 

Illuminated 

Error in Fan Rotation 

Flashing 

Warning for Fan Rotation 

Off 

Fan in Normal Operation 

*1

 

SYS Green 

Illuminated In 

Normal 

Operation 

Off Operation 

Suspended 

*2

 

*1  LED lamp should be off when the fan is not connected. 

*2  There may be a case that this LED lamp is off even if there is an input of AC power when 

in parallel operation in low load as there is a case that only some of the power sources are 
in operation. It should turn on when load increases and all the power source starts 
working. 

 

[7] Power Supply Terminals

 

Terminals to connect cables for AC power input, frame grounding and output voltage 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Connector Names : DT-5C-B84W-6717-07 (DINKLE) 

Pin Number Signal 

Description 

1 +24V 

24V Output Terminals (Pin 1 and 2 are connected inside) 

2 +24V 
3 0V 

0V Output Terminals (Pin 3 and 4 are connected inside) 

4 0V 

5 FG 

Frame Grounding Terminal (grounding terminal connected to 
the body of power source)

*1

 

AC (N) 

AC Input Neutral Terminal (on grounding) 

AC (L) 

AC Input Live Terminal (on non-grounding) 

*1 “   ”

 

means functional grounding terminals. 

 

*  Recommended cable size : From AWG14 to 18

 