External Dimensions
●
PSA-24
●
PSA-24L
Name and Function of Each Part
[1] Connector for FAN Connection
It is the connector for fan connection when using at 330W for the continuous rated output.
Connector Names on PCB side : DF11-4DP-2DS (24) (HIROSE ELECTRIC CO., LTD.)
Pin Number Signal
Description
1
24V
Fan Power Supply
2 CONNECT
Connection Recognition Signal
(Connected : H / Unconnected : L)
3
GND
GND for Fan
4
PULSE
Fan Rotation Pulse
[2] Connector for Communication
It is the connector to monitor the status data inside the power source by communication.
There are two inlets in order to enable communication with multiple power sources in
multi-drop wiring.
It can be connected to either of the inlets because the differential signal
on each inlet is short-circuited with each other inside. The connector on the cable is
enclosed.
Connector Names on PCB side : 0221-26-6615-06THT (DINKLE)
Connector Names on Cable Side (Accessories) : 0221-2403 (DINKLE)
Pin Number Signal
Description
1
SD+
Positive Side of RS485 Differential Signal
2
SD-
Negative Side of RS485 Differential Signal
3 GND
4
SD+
Positive Side of RS485 Differential Signal
5
SD-
Negative Side of RS485 Differential Signal
6 GND
* There is no impact to the operation of the power source itself even if there is no
communication connector connected.
[3] Address Switch for Communication
Set up the slave address assignment in communication for when connecting multiple
power sources in multi-drop wiring and monitoring the status by communication.
Switch Names : DRR7016C (NIDEC COPAL ELECTRONICS CORPORATION)
Item Description
Initial Setting
“0”
Range for
Setting
“0” to “F”
[4] Fan Unit
Unit to connect when using at 330W for continuous rated output (PSA-24L)
[5] FAN Alarm LED Lamp
[6] Normal Operation LED Lamp
This power source is equipped with two types of LED lamps as shown below.
Description on
Panel
Display
Color
Status Description
FAN Orange
Illuminated
Error in Fan Rotation
Flashing
Warning for Fan Rotation
Off
Fan in Normal Operation
*1
SYS Green
Illuminated In
Normal
Operation
Off Operation
Suspended
*2
*1 LED lamp should be off when the fan is not connected.
*2 There may be a case that this LED lamp is off even if there is an input of AC power when
in parallel operation in low load as there is a case that only some of the power sources are
in operation. It should turn on when load increases and all the power source starts
working.
[7] Power Supply Terminals
Terminals to connect cables for AC power input, frame grounding and output voltage
Connector Names : DT-5C-B84W-6717-07 (DINKLE)
Pin Number Signal
Description
1 +24V
24V Output Terminals (Pin 1 and 2 are connected inside)
2 +24V
3 0V
0V Output Terminals (Pin 3 and 4 are connected inside)
4 0V
5 FG
Frame Grounding Terminal (grounding terminal connected to
the body of power source)
*1
6
AC (N)
AC Input Neutral Terminal (on grounding)
7
AC (L)
AC Input Live Terminal (on non-grounding)
*1 “ ”
means functional grounding terminals.
* Recommended cable size : From AWG14 to 18