CM-080GE/CM-080GE-RA / CB-080GE/CB-080GE-RA
- 43 -
10.2.2.1 LVAL_sync timing
EPS LAVL SYNC
TRIG
2L(min)
LVAL
1L(max)
CCD
Exposure
EEN
FAVL
(Ful
l: 86 us to 133us
Vbinnig: 117us to 169us )
Exposure
Trigger is input during FVAL HIGH period,
automatically set to LVAL sync mode
2L to 3L
Fig. 28. Edge Pre-select LVAL sync Timing
10.2.2.2 LVAL_async timing
5.776μ s± 1μ s
1L(min)
CCD
Exposure
EEN
Exposure
FAVL
2L
3L
(Full: 86us to 133us
Vbinnig: 117us to 169us )
Trigger is input during FVAL LOW period,
automatically set to LVAL s-SYNC mode
EPS LVAL a-SYNC
Trigger
to
Fig.29. Edge Pre-select LVAL async Timing