![IAI AP-3200T-PMCL Скачать руководство пользователя страница 4](http://html2.mh-extra.com/html/iai/ap-3200t-pmcl/ap-3200t-pmcl_command-list_3178275004.webp)
4
.
Command List
(
Short
ASCII Command
)
4
.
1
.
GenCP Bootstrap Register
Name
Access
Short
ASCII
Values
MIN
MAX
DEFAULT
Description
DeviceVendorName
R/O
DVN
"JAI Corporation"
-
-
-
DVN?<CR><LF>
DeviceModelName
R/O
MD
"AP-3200T-PMCL"
"AP-1600T-PMCL"
-
-
-
MD
?<CR><LF>
DeviceVersion
R/O
DV
Version of the device.
(e.g. “0.1.0.0” )
-
-
-
DV?<CR><LF>
DeviceSerialNumber
R/O
ID
Device's serial number.
-
-
-
ID?<CR><LF>
DeviceUserID
R/W
UD
User can save and load free text.
(64 or less characters)
UD=[Param.]<CR><LF>
UD?<CR><LF>
4
.
2
.
Technology Specific Bootstrap Register
Name
Access
Short
ASCII
Values
MIN
MAX
DEFAULT
Description
DeviceSerialPort
SupportedBaudRate
R/O
SBDRT
READ: Indicate supported
Baudrate.
1(0x01):BaudRateMax_9600
3(0x03):BaudRateMax_19200
7(0x07):BaudRateMax_38400
15(0x0F):BaudRateMax_57600
31(0x1F):BaudRateMax_115200
63(0x3F):BaudRateMax_230400
127(0x7F):BaudRateMax_460800
255(0xFF):BaudRateMax_921600
Multiple bits may be set
according to the capability of the
device.
1(0x01
)
255(0xF
F)
31(0x1F)
SBDRT?<CR><LF>
This camera supports 9600bps,
19200bps, 38400bps, 57600bps, and
115200bps.
DeviceSerialPort
BaudRate
(R)/W
CBDRT
READ: Indicate current baud rate
WRITE: Set any bit of baud rate
1(0x01):Baud9600
2(0x02):Baud19200
4(0x04):Baud38400
8(0x08):Baud57600
16(0x10):Baud115200
A single bit may be set according
to the current baudrate setting.
0 is an invalid value.
1(0x01
)
16(0x10)
1(0x01)
CBDRT=[Param.]<CR><LF>
CBDRT?<CR><LF>
In case of WRITE execution
(change baud rate), it needs to
control in the proper sequence
between Host and Camera.
(Refer to the section 3.3)