i4Technology BugHunter Professional CR-01 Скачать руководство пользователя страница 6

this action until you find the place with the maximum radiation. 

 
4.3 Scan the detected place with maximum radiation for wireless «bugs», if you want, you can manually adjust 

device sensitivity by sliding your finger up or down the touch panel. 

 
4.4  If  during  scanning  for  a  constant  signal,  all  (or  part)  of  the  LEDs  quickly  turn  on  and  off,  please  switch 

operating mode to search of pulse signal. 

 
4.5 In case of detection of a place with a maximum level of unknown radiation, the device can be switched into 

feedback mode. If you hear a characteristic whistle out of the device, it means that a wireless microphone (bug) is 
transmitting at the moment. 

 
4.6 The "Guard" mode should be used when there is no unknown radiation around. It can take some (about 5 

sec.) time for the device to automatically adjust the background radiation. After the adjustment process, the device 
switches  into  “Guard”  mode  -  "AK"  indicator  will  light  up  for  a  short  time  period.  If  an  unknown  radiation  is 
detected, the device will alarm with a steady signal, when the radiation is over it returns to guard mode. 

 
4.7 If necessary, recharge the built-in battery of the device via cable and AC adapter supplied. After charging is 

over the red light will be off (item 10). In addition, the charging process is dynamically visualized with a backlight 
of the touch-panel. 

 
4.8.  Some recommendations on device usage:  
 

- Before starting the searching process, switch off any radio-emitting devices if possible (Wi-Fi, cell phone in 

active mode, computers and other household  and office equipment).  It  simplifies  the  process  by  eliminating  extra 
noise, and allows using higher level of sensitivity. 

-  In the  "search"  mode, the  level  of sensitivity of the  device should be  adjusted and  you should  go  near  the 

suspicious  object.  It  is  desirable  to  scan  with  the  help  of  the  device  places  where  most  likely  "eavesdropping" 
devices could be installed.  

- The most likely locations of eavesdropping and spying devices are: cavities and crevices in baseboards and 

walls,  behind  radiators,  remote  places  in  the  cabinets,  moldings,  ceiling  cavity,  ventilation  shafts,  pieces  of 
furniture, household items, flowers, board panel of the car, seat, etc. 

- If the device detects a signal, it will alarm you with a sound and show it on the LED scale. The closer device 

is to the transmitter, more glowing LED scale is. 

- While scanning, it is preferably to use two different search modes: detection of usual analog wireless "bugs" 

and digital ones.  

- Usually, the "Guard" mode should be turned on if you need to have a  constant control of the situation, for 

example,  during  negotiations.  The  device  keeps  scanning  the  area  in  this  mode.  It  will  alarm  you  if  any  wireless 
“bug” or hidden transmitting cell phone is disclosed.  

-  "Feedback"  mode  is  used  to  search  for  hidden  microphones  (wireless  "bugs"),  operating  in  analog  mode. 

This  allows  the  wireless  "bug"  to  capture  the  sound  emitted  by  the  device,  and  broadcast  it.  The  radio  signal  is 
detected  and  its  strength  is  increased  by  the  device.  As  the  result,  the  circle  closes  up  and  the  device  produces  a 
characteristic "whistle." “Feedback” mode is the most accurate method of "bugs" detection; it essentially reduces the 
search time. 

 

5. Package contents 

 

Package contents of the device can be seen in Table 1. 

Table 1 

   № 

Item name 

Quantity 

Notes 

Field indicator  BugHunter™  Professional CR-
01  INTK.411153.005 

 

microUSB cable 

 

AC adapter 

 

Packing box 

 

User manual BA English Manual

 

 

 

Содержание BugHunter Professional CR-01

Страница 1: ...Innovations ltd www ba detect com User manual INTK 411153 005 RE CONTENTS Device description and operation 1 Technical specifications 2 Device components 3 Structure and functioning 4 Operation proced...

Страница 2: ...ic adjustment of background radiation levels 9 Extended operating temperature range 10 Design and manufacturing made in Russia using high quality components set 11 Can operate in three modes analog si...

Страница 3: ...4 2 Power consumption W no more than 0 16 Frequency range MHz 10 3500 Sensitivity mV m not less than 50 Dynamic range dB up to 70 Modes of operation search guarding feedback Detection range of radio...

Страница 4: ...onic modules that are covered with a safety film The front panel of the device item 2 is a keyboard with touch sensitive buttons and a touch panel The following controls and indicators are located on...

Страница 5: ...is flashing the device is in search of pulse digital transmitters digital eavesdropping devices cell phones c When the MODE is off and AK LED lights up for short time period and then goes off the dev...

Страница 6: ...higher level of sensitivity In the search mode the level of sensitivity of the device should be adjusted and you should go near the suspicious object It is desirable to scan with the help of the devi...

Страница 7: ...d and accepted in accordance with the applicable technical documentation and validated Quality Department stamp ___________________ 9 MANUFACTURER WARRANTY 9 1 i4Technology Russian vendor and manufact...

Страница 8: ...t sales paraben sticks co uk Copyright I4 technology Sold exclusively to BA Detect for the vertical channels of B2B covert surveillance resellers in Western Europe and North America Questions concerni...

Страница 9: ......

Отзывы: