CAMERA PARTS AND DEFINITIONS
SAFETY
When installing your Ax63Z camera be sure to avoid:
• excessive heat, such as direct sunlight or heating appliances
• contaminants such as dust and smoke
• strong magnetic fields
• moisture and humidity
• areas with mechanical vibrations
• fluorescent lamps or objects that reflect light and unstable light sources
• temperatures below -40° C (-40° F) and above 50° C (122° F
).
To avoid electrical shock and to preserve the product warranty,
DO NOT
disassemble the
camera. Refer servicing to qualified personnel only.
POWER SUPPLY
This camera accepts PoE+
(IEEE 802.3at) or AC24V
power for indoor installations.
Use AC24V power only for low-temperature outdoor installations.
Maximum power consumption for outdoor installations with heater on: 36W.
Ensure the supplied voltage meets the power consumption requirements of this camera
before powering the camera on. Incorrect voltage may cause irreparable damage to the
video camera and will effectively void the camera warranty.
CLEANING
• For maximum optical clarity, the camera dome or lens must remain clean. Use a soft,
dry cloth to remove finger prints or dust from the dome cover.
• Use a blower to remove dust from the lens.
• Do not use volatile solvents such as alcohol, benzene, or thinners, as they may dam-
age the surface finishes.
1.
1.5” Female coupler. Remove when using with
i3D702 and i3D703 brackets and replace with
1.5” Male coupler (provided, “
A
”).
2.
Drop protection/safety wire. Secure to a solid
surface during installation to prevent accidental
camera drop.
3.
Main signal connector.
4.
RJ45 Ethernet PoE+ Port. Connect to the network
switch. Use RJ Female/Female coupler (E) if
needed. Camera supports PoE+ power in indoor
installations.
5.
AC24V Power Connector (Black/White). Connect to
a power supply. Make sure to connect the terminals
to correct ports. (Black+/White-). Do not use if
installing indoors and using PoE+ power.
3MP High-Speed Network Dome Camera
Ax63Z
User Manual
i3-TRNG-CAMS-
Ax63Z
.indd
Rev
. 200113
QR Code for Complete
User Manual and ACT
to view and
download
AnnexxusConfigurationTool v1.5 (ACT)
and the full
User Manual.
Contact our Technical Support team at:
1.877.877.7241
or
if you have any questions or
concerns regarding camera installation or if you require software
services or support.
5
9
10
11
14 3/16”
(360.19mm)
3.7”
(94mm)
8.5” (216.14mm)
R3.45”
(88.5mm)
2
3
8
12
4
6
7
Alarm In:
5 (Blue); 6 (Green); GND (White)
Alarm In:
1 (Red); 2 (Brown)
Alarm In:
3 (Yellow); 4 (Orange)
Factory Default
(Pink/Gray)
Audio In
(Black/White)
Restart
(Orange/White)
Alarm Out:
Open (Light Green);
COM (Black); Closed (Purple)
RJ45:
Ethernet, PoE+
AC24V
Power
(Black/White)
PACKAGE CONTENTS
Ensure that the items received match those listed on the order form and the packing slip.
In addition to this manual and a fully assembled camera, the dome camera packing box
includes:
A.
1.5” Male coupler x1
(Use with i3D702 and i3D703 PTZ brackets)
B.
Blind set screw x1
C.
Hex driver (Allen key) x1
D.
Security driver (Torx key) x1
E.
RJ45 Female/Female coupler x1
B
C
D
E
A
MOUNTING OPTIONS
Compatible i3 Mounting Accessories:
i3D702 - Pendant Surface Pipe mount bracket. Use 1.5” Male Coupler (A).
i3D703 - Wall Mount bracket. Use 1.5” Male coupler (A).
i3D704 - Junction Box Gooseneck Wall Mount 1.5” NTP bracket
i3D705 - Junction Box Pendant Wall Mount 1.5” NTP bracket
i3D706 - Parapet Mount 1.5” NTP bracket
i3D707 - Corner Mount for i3D703
i3D708 - Pole Mount for i3D703
i3D709 - Pipe Extension 1.5” NTP
i3D710 - Sunshield Hood
Mounting Type
Additional Accessories required
Horizontal Wall Mount
i3D703 or i3D704
Parapet Mount
i3D706
Pendant Mount
i3D702 or i3D705
Corner Mount
i3D707
Pole Mount
i3D708
6.
Restart (Orange/White). Use jumper cable to short two PIN connectors for
10 seconds
to restart Ax63Z.
7.
Audio In (Black/White). Connect to an external audio input device (microphone) to
record audio stream with video.
8.
Alarm Out (Light Green - Open; Black - COM, Purple - Closed). Connect to the alarm
out device (speaker, strobe light, etc.)
9.
Alarm In 1-2 (Red - #1, Brown - #2). Connect to the alarm in device (motion
detector, temperature sensor, etc.)
10.
Alarm In 3-4 (Yellow - #3, Orange - #4). Connect to the alarm in device.
11.
Alarm In 5-6 (Blue - #5, Green - #6, White - GND). Connect to the alarm in device.
12.
Factory Default (Pink/Gray). Use jumper cable to short two PIN connectors for
10
seconds
to return Ax63Z to factory defaults.
1