background image

16

It is necessary to register users who directly operate this product, or PCs (hosts) that access through the network such as LAN. 
Up to 32 users can be registered.
It is possible to register the following for the user information.

Item

Description

User name

User name is to be registered to log in to the recorder. The user name will be entered at the time 
of login.

Password

Password is to be registered to log in to the recorder together with the user name. The pass-
word will be entered at the time of login.

Level

Users are classified into the following levels depending on the available operations.
Administrator/Manager/Operator/Viewer/Logged out 
The administrators can perform all the configurations and operations. It is possible to select in 
advance the functions that can be controlled by users at other levels. (

 Operating Instructions )

Priority level

Priority level indicates the operational priority. Users at each level are assigned the fixed priorities 
ranging from "0" (Highest) to "4" (Low).
 

Administrator 0 

Highest

 

 Manager 

High

 

 Operator 

2

 Viewer 

3

 

Logged out  4 

Low

When the two or more users at the same level perform the same operation, the recorder will be 
controlled in accordance with the latest operation.

Default screen

Select the live image display screen of the main monitor/PC screen to be displayed immediately 
after login.

When operating from a PC via a network

Operation of the recorder can be made using a PC via a network. Up to 16 hosts (PCs) can access the recorder at the same 
time.
When another host (PC) tries to log in to the recorder after 16 hosts (PCs) have already logged in, the user with the lowest priority 
will be logged out. When the user who is trying to log in has the same priority as the users who have already logged in, the user 
whose login is the earlier is logged out.

When accessing the recorder from a PC via a network, the log-in authentication method is different as follows depending on the 
"User authentication" settings of the "Basic" tab under "User management" under "Advanced" from the setup menu.  
(

 Operating Instructions)

User authentication setting

User/Host to log in

Remarks

Off

Log in as an administrator.

On (default)

Log in as a registered user.

The login window will be displayed.

User/Host management

Содержание WJ-NX310K Series

Страница 1: ...tions carefully and save this manual for future use The model number is abbreviated in some descriptions in this manual Important Information Network Disk Recorder Model No WJ NX310K Series For profes...

Страница 2: ...et outlet is located installed near the equipment and is easily accessible This product is a professional equipment Functional earthing functional grounding US symbol Direct current symbol Alternation...

Страница 3: ...emarks 6 About HEVC High Efficiency Video Coding patents 6 Copyright 6 Disclaimer of warranty 7 Network security 7 Limitation of liability 7 Precautions 8 Major operating controls and their functions...

Страница 4: ...tically recognized and settings can be configured without operations from a PC 1 Recorded images can easily be searched using calendar or time line A PC will be necessary for some of the camera settin...

Страница 5: ...to turn off the AC power without having to stop recording or perform other operations It does not guarantee that the equipment will not malfunction in the event of all possible power interruptions In...

Страница 6: ...stem requirements OS Microsoft Windows 10 Microsoft Windows 11 Web browser Microsoft Edge Google Chrome Mozilla Firefox CPU Intel CoreTM i7 860 Memory 4 GB or more Monitor 1920 1080 pixels or more 24...

Страница 7: ...IES OF MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE OR NON INFRINGEMENT OF THE THIRD PARTY S RIGHT THIS PUBLICATION COULD INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS CHANGES ARE ADDED...

Страница 8: ...to observe this may cause electric shock Do not connect disconnect the power plug with wet hands Failure to observe this may cause electric shock Avoid doing anything that can damage the power cord p...

Страница 9: ...ces Handle them with care It is possible to damage them if they are moved while their motors are still running Please be forewarned that any loss of information on the HDD is not guaranteed under any...

Страница 10: ...boot becomes necessary Disclaimer of warranty on recoded data i PRO Co Ltd assumes no responsibility or liability directly or indirectly for failure of recording or editing including loss of data due...

Страница 11: ...that the respective hard disk drive is not being accessed Recording indicator REC Lights orange when recording is being performed Alarm indicator ALARM Blinks when an alarm occurs and lights when the...

Страница 12: ...he HDD bracket The screws do not detach from the bracket HDD bracket Install the HDD Refer to Installation of the hard disk drive in the operating instructions for the installation of the HDD Screw ho...

Страница 13: ...the PC are connected to different network Network port Camera PC port CAMERA PC Connect the recorder with a PC and cameras via a network compatible with 10BASE T 100BASE TX or 1000BASE T Only the rig...

Страница 14: ...inches Tighten the power cord at 15 cm to 20 cm 5 7 8 to 7 7 8 inches from the connector and fix it to the clamp mount Cut the unnecessary part of the power cord clamp as necessary Fitting of the cabl...

Страница 15: ...art Step 2 Close the clamp Step 3 Slide the cable clamp toward the connector end of the connection cable and then hold the connector end of the connection cable Make sure that the connection cable is...

Страница 16: ...anager 1 High Operator 2 Viewer 3 Logged out 4 Low When the two or more users at the same level perform the same operation the recorder will be controlled in accordance with the latest operation Defau...

Страница 17: ...gh speed serial interface USB3 0 3 Alarm Control connector Alarm input 1 9 1 Alarm output 2 Network error output 2 Alarm reset input 1 Emergency recording input 1 HDD error Recording error output 2 Ca...

Страница 18: ...GQP3682ZA i PRO Co Ltd Tokyo Japan https www i pro com Authorised Representative in EU i PRO EMEA B V Laarderhoogtweg 25 1101 EB Amsterdam Netherlands i PRO EMEA B V UK Branch 1010 Cambourne Business...

Отзывы: