PROTECTION FROM ELECTRIC SHOCK

 

Shut down power to the entire installation at the building’s main power distribution 
board and lock out power (by removing the fuse for example) before carrying out any 
installation or maintenance work. 

Disconnect the fixture from AC power before removing or installing any cover or part 
and when not in use. 

Always ground (earth) the fixture electrically. 

Use only a source of AC power that complies with local building and electrical codes 
and has both overload and ground-fault (earth-fault) protection. 

Connect this fixture to AC power either using the supplied power cable or via 3-
conductor cable that is rated minimum 20 amp, hard usage. Suitable cable types 
include ST, SJT, STW, SEO, SEOW and STO.
 
The voltage and frequency at the power outlet are the same as the voltage and 
frequency applied to the power inlet. Only connect devices to the power outlet that 
accept this voltage and frequency. 

Before using the fixture, check that all power distribution equipment and cables are in 
perfect condition and rated for the current requirements of all connected devices.
 
Do not use the fixture if the power cable or power plug are in any way damaged, 
defective or wet, or if they show signs of overheating. 

PROTECTION FROM FIRE

 

Do not attempt to bypass thermostatic switches or fuses. Replace defective fuses 
with ones of the specified type and rating only. 

Provide a minimum clearance of 0.1 m (4 in.) around fans and air vents.
 
Do not modify the fixture 

Apart from I-PIX accessories do not stick filters, masks or other materials directly 
onto the light. 

SATELLITE     USER MANUAL                                         PAGE 4

Содержание Satellite

Страница 1: ...JAN 2009 RELEASE USERS MANUAL...

Страница 2: ...ORY page 10 CREATING A MEMORY page 11 RECALLING A MEMORY page 14 CREATING A CHASE page 15 THE TECHNICAL STUFF TECHNICAL SPECIFICATIONS page 17 UNIT DIMENSIONS DRAWING page 18 TROUBLE SHOOTING page 19...

Страница 3: ...ling powering or servicing the fixture follow the safety precautions listed below and observe all warnings in this manual If you have questions about how to operate the fixture safely please contact I...

Страница 4: ...T SJT STW SEO SEOW and STO The voltage and frequency at the power outlet are the same as the voltage and frequency applied to the power inlet Only connect devices to the power outlet that accept this...

Страница 5: ...es suspended from them and must be installed as described in this manual Check that all external covers and rigging hardware are securely fastened Block access below the work area and work from a stab...

Страница 6: ...nsures that the Satellite is a very competitive and versatile unit with features that make it easy to use and set up For ease of operation compatibility and versatility the Satellite can be set into e...

Страница 7: ...amp next to the input cable shown in fig 2 The Satellite is a very simple light to rig all that is necessary is to bolt your clap of choice to the yoke obviously selecting one that is well capable of...

Страница 8: ...urve First press the button above the MENU legend 2 select appropriate mode The Satellite offers a choice of two operating modes Both of which are described in detail below To select a mode Keep the b...

Страница 9: ...7 cells are treated as 1 with the 3 channels red green blue affecting the whole lamp ch1 red ch2 green ch3 blue MODE 3 5 channels 8 bit ideal for fast programming or limited dmx line space with overa...

Страница 10: ...ltiple or complex memories is to give the light the desired colour information using a lighting desk or similar DMX generating device and use the STORE function 1 Connect the light to the desk in the...

Страница 11: ...T The default value for the MINT is 100 intensity full If you wish to alter this value use the buttons above and below the UP DOWN legends until you have the desired value 4 When happy with the MINT v...

Страница 12: ...ted with the second colour GREEN default 0 In the same way if you wish to alter this value use the UP DOWN buttons to give you the desired If you require 100 press the DOWN button 7 When happy with th...

Страница 13: ...ou may have made a mistake or you have just changed your mind then you can return to the start of the memory by pressing MEM button and repeating the above process If you are happy with you memory you...

Страница 14: ...mory MEM 01 This will come on automatically 4 To select any other memory simply use the UP DOWN buttons until you find the memory you want The memories will come on as you select them IF YOU WISH YOUR...

Страница 15: ...hat the colour is held constant for Select the appropriate time in seconds using the UP DOWN buttons 4 When you are happy with the WAIT TIME press the button above WAIT TIME once Now the XFADE TIME cr...

Страница 16: ...hase will run through all the memories numbered between the first and last step Choose which memory you would like to be the last step of your chase using the UP DOWN buttons 7 Once you are happy with...

Страница 17: ...t socket Neutrik NC5MDL1 XLR 5 pole chassis socket DMX output socket Neutrik NC5FDL1 XLR 5 pole chassis socket Mains in out sockets current 16 A max at 240 VAC Light Output beam angle six degrees in a...

Страница 18: ...Satellite dimensions drawing SATELLITE USER MANUAL PAGE 18...

Страница 19: ...y or of the exact nature of any encountered problem I pix provides the information contained herein only as a guide Mains supply keeps tripping out blowing fuses Does the mains supply trip before the...

Страница 20: ...ed Note the LCD screen flashes intermittently when no data is present The fuse on a unit repeatedly blows Are you fitting right rating type of fuse into unit Contact I pix for more specific help with...

Страница 21: ...lers speci cations for the product abuse neglect or accident THE ABOVE WARRANTY IS EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED I PIX SPECIFICALLY DISCLAIMS THE IMPL...

Страница 22: ...replacement of goods or repair of defects or refund of the purchase price at the Sellers sole option The above warranty does not apply to defects resulting from the improper or inadequate maintenance...

Страница 23: ...tone Mill Broadstone Road Houldsworth Village Cheshire SK5 7DL Telephone 44 0 161 443 4140 Web www i pix uk com E Mail service i pix uk com Located 4 miles from Manchester airport and the city centre...

Страница 24: ...genized RGB output with no colour separation A fresh look from an led fixture the bb 7 is completely self contained device rated at 210 watts drawing 0 9 amps at 240 volts Super fast super smooth cont...

Страница 25: ...CAPS The shape of the light beam from the Satellite can be altered by placing a lens cap containing diffracting holographic film on the the light The light comes with a choice of four beam angles 10 d...

Страница 26: ...ACCESSORIES FOR THE BB4 BB4 SINGLE YOKE for rigging a BB4 vertically BB4 DOUBLE YOKE for rigging 2 BB4s vertically SATELLITE USER MANUAL PAGE 26...

Страница 27: ...mbined power data socket OUTPUT CABLE 16A female Cform 5 pin female XLR to CEEP combined power data plug COMBINED POWER DATA CABLE CEEP combined power data plug to CEEP combined power data socket In L...

Отзывы: