Содержание MHF-SW23

Страница 1: ...HF SW23 SMA ADAPTERS Part No 90604 0001 90605 0001 Instruction Manual 2 S20234 April 24 2020 Y Imaji K Yufu Y Hashimoto 1 S13487 December 16 2013 S Hamada K Yotsutani T Takano 0 S13293 July 24 2013 H...

Страница 2: ...e operation and cautions on test procedures Refer to HIM 13004 for instruction manual on MHF SW23 before usage SMA High Cycle Type Inspection SMAAdaptor Product name MHF SW23 RECEPTACLE HIGH CYCLE SMA...

Страница 3: ...components and causes inspection failure MHF SW23 RECEPTACLE HIGH CYCLE SMAADAPTER P N 90604 0001 MHF SW23 RECEPTACLE HIGH CYCLE F SMAADAPTER P N 90605 0001 Figure 2 Flange dimensions Flange dimensio...

Страница 4: ...HIGH CYCLE F SMAADAPTER P N 90605 0001 Pressure plate After fixing flange use 0 57Nm torque wrench to tighten SMA P side to secure to inspection jig 0 57N SMA P Operating error may occur in case of c...

Страница 5: ...of misalignment mating 2 Self centering structure Floating mounting plate To measuring instrument Assure that the cable weigh does not tilt MHF SW23 High CYC ADAP MHF SW23 HIGH CYC ADAP Pressure plat...

Страница 6: ...should have floating mechanism and pressing mechanism by a built in spring 3 After mating adapter to a receptacle the total of the loads shall be setup within 5 to 10 N 4 Tilting more than allowable...

Страница 7: ...LE HIGH CYCLE F SMA ADAPTER Figure 10 Allowable angular of misalignment mating Figure 9 Allowable axial misalignment length MHF SW23 2 Figure 8 To measuring instrument Assure that the cable weigh does...

Страница 8: ...to the center axis 3 Stroke width form bottom of the flange to tip of outer contact A shall be managed within 24 35 0 85 4 Built in floating mechanism of the adapter makes the adapter to tilt easily 5...