background image

 

CABLINE

®

-CA IIF Instruction Manual

 

Document No. 

HIM-17029

 

 

 
 

 

9

  / 

11

 

Confidential C                                                                   

②図 16 の様に、プラグコネクタの両側を水平に引っ張り、抜去を行う。 

            As shown in Fig.14, hold both ends of the Plug connector and withdrawal it parallel. 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 

<注 10/Caution 10> 

              抜去時の水平方向のこじり角度は、5°以下でお願い致します。 
              5°以上での抜去は、コネクタ変形の原因となります。 
              Please keep withdrawal slant 5 ° or less in horizontal direction. 
              By withdrawing with the slant more than 5°, deformation of the connector will occur. 

 

 
 
 

 
 
 
 
 
 
 
 
 

 

コネクタ両側を水平に引っ張る 

Pull both ends of connector horizontally 

図 16 (Fig 16.)   

 

図 17 (Fig 17.)   

Содержание CABLINE-CA IIF

Страница 1: ...No HIM 17029 Confidential C I PEX Inc QKE DFFDE09 03 REV 8 CABLINE CA IIF Part No 20856 040T 01 Instruction Manual 0 S17632 November 13 2017 Y Sasa T Masunaga H Ikari Rev ECN Date Prepared by Checked...

Страница 2: ...nector Product Name CABLINE CA IIF SHELL ASS Y Part No 20856 040T 01 Receptacle connector Product Name CABLINE CA II RECEPTACLE Part No 20682 040E 0 part shows the variation Please refer to a drawing...

Страница 3: ...et so that the datum pin mark of Plug connector and Receptacle connector are matched 4 As shown in Fig 4 push both ends of Plug connector horizontally and confirm there is no gap Datum pin of Plug con...

Страница 4: ...p as shown in Fig 3 Cover Cover Shell Do not close a cover if slant mating was confirmed Interference of a cover and a receptacle shell may deform the connector 2 Caution 2 Shell Please insert the con...

Страница 5: ...than 5 deformation of the connector will occur 4 Caution 4 Lock Bar ass y Cover FPC FPC If cover is opened up more than its stopped position cover edge may damage the FPC 5 Caution 5 8 8 At starting t...

Страница 6: ...ion to avoid deformation or any connector damage 8 Caution 8 Please do not apply force toward the PCB side to the plug connector in insertion PCB will be damaged like below and it may cause the discon...

Страница 7: ...er down toward the PCB direction at a same time to lock receptacle shell and lock bar Push Push the lock cover bar downward Locked condition OK NG Receptacle shell Receptacle shell is exposed Lock bar...

Страница 8: ...release the lock Rotate the cover bar as shown on the bottom right figure 9 Caution 9 Lock bar ass y Lock bar ass y When releasing the lock do not lift by the center of the lock bar ass y There are p...

Страница 9: ...14 hold both ends of the Plug connector and withdrawal it parallel 10 Caution 10 5 5 Please keep withdrawal slant 5 or less in horizontal direction By withdrawing with the slant more than 5 deformati...

Страница 10: ...ssibilities to cause the Lock bar ass y and connector deformation 12 Caution 12 Please do not apply force toward the PCB side to the plug connector in withdrawal PCB will be damaged like below and it...

Страница 11: ...connector to the vertical direction It may cause the receptacle connector s deformation FPC FPC FPC In handling the FPC please pay attention not to apply excessive force to the connector or the FPC It...