background image

 

CABLINE-CA II PLUS PLUG Assembly Manual 

Document No. 

ASM-16004

 

 

 
 

 

9

  / 

17

 

Confidential C                                                                                                                                                                                                   

           

⑤芯線をパルスヒートにて半田付けする。  半田付け状態は、下記

Photo.3

参照。

 

    Center-conductors are soldered with pulse heater. See photo.3 of soldering condition. 

 

Photo.3 AWG#40 

 

        注意:

PLUG HSG ASS'Y

SHELL

底面には、

Fig.4

の箇所に凸形状を設けておりますので、

 

                パルスヒート受け

JIG

には、干渉しないように凸形状の逃がしを設けてください。

 

       

Caution: The SHELL bottom side of PLUG HSG ASS'Y has convex shape at the points shown in Fig.4, 

so please make escape shape on the receiving jig of the pulse heater to prevent interference. 

 

 

60P 

16.0 

29.4 

 

 

 

Fig.4 The SHELL bottom side of PLUG HSG ASS'Y 

Unit: mm 

Содержание 20679-020T-01

Страница 1: ...ASM 16004 Confidential C I PEX Inc QKE DFFDE09 04 REV 8 CABLINE CA II PLUS PLUG Part No 20788 0 T 0 Assembly Manual 0 S16442 June 29 2016 T Masunaga H Mashima J Tateishi Rev ECN Date Prepared by Check...

Страница 2: ...BLE ASS Y 20788 0 T 0 Discrete P N HOUSING ASS Y 20680 0 T 01 LOCK BAR ASS Y 20789 0 T 0 SHELLA 3204 0 1 3 Fixtures 3 1 Components and Instruments used in the condition confirmation Pulse heater Heate...

Страница 3: ...d heat temp 300 320 rise time 0 5sec holding time 3 0sec Heater tip Pressure 5 10N This pulse heat condition was evaluated and confirmed by our pulse heat jig and instruments The most optimum conditio...

Страница 4: ...004 4 17 Confidential C 5 Work procedures 5 1 Soldering of center conductor The cables have to be fabricated as shown below in advance of soldering Pos A 60P 23 60 Recommended MICRO COAX dimension MIC...

Страница 5: ...CABLINE CA II PLUS PLUG Assembly Manual Document No ASM 16004 5 17 Confidential C...

Страница 6: ...CABLINE CA II PLUS PLUG Assembly Manual Document No ASM 16004 6 17 Confidential C...

Страница 7: ...tc and please confirm all contacts were applied flux Photo 1 After applying flux Photo 2 Please do not apply flux too much like Photo 2 It can cause flux splash or leak to the mating area Photo 2 Extr...

Страница 8: ...set and locate solder bar at center of connector HSG ASS Y Fig 1 Set of solder bar Set the cable SHELL Fig 3 0 2MAX Setting discrete cable is to protect 0 2MAX as Fig 3 There is danger that Center Con...

Страница 9: ...See photo 3 of soldering condition Photo 3 AWG 40 PLUG HSG ASS Y SHELL Fig 4 JIG Caution The SHELL bottom side of PLUG HSG ASS Y has convex shape at the points shown in Fig 4 so please make escape sha...

Страница 10: ...e after soldering 5 2 SHELL A Cautions in treating SHELL A SHELL A SHELL A SHELL A is delivered in the reel with a carrier The following is the method to cut SHELL A from Carrier Cut Line Cut carrier...

Страница 11: ...6004 11 17 Confidential C Plug SHELL A Detail of Notch Caution By pulling like the photo below to cut off by force Red arrow direction burrs and transformation can be caused Photo 8 Bottom side view P...

Страница 12: ...HOUSING ASS Y LOCK BAR ASS Y LOGO MARK LOCK BAR ASS Y is assembled to HOUSING ASS Y I PEX logo mark side of LOCK BAR ASS Y facing the cable side Fig 5 Assembly of LOCK BAR ASS Y 5 4 SHELLA Assembly of...

Страница 13: ...CABLINE CA II PLUS PLUG Assembly Manual Document No ASM 16004 13 17 Confidential C Fig 7 SHELLA HOUSING ASS Y SHELLA is assembled from the upper side of HOUSING ASS Y Fig 7 Assembly of SHELL A...

Страница 14: ...y Manual Document No ASM 16004 14 17 Confidential C SHELLA SHELL Fig 8 Confirms whether SHELLA is assembled properly Whether SHELL locks are assembled properly Fig 8 point Fig 8 The assembly confirmat...

Страница 15: ...9 10 Fig 13 10 SHELLA B and GND BAR are soldered with the soldering iron at all designated points Fig 9 10 point Refer to Fig 13 for a limit of the solder height For conditions of Soldering iron refer...

Страница 16: ...No ASM 16004 16 17 Confidential C SHELL A SHELL B Fig 11 10 SHELL A and SHELL B are soldered with the soldering iron at all designated points Fig 11 point Conditions of Soldering iron refer to sheet...

Страница 17: ...t No ASM 16004 17 17 Confidential C 5 5 Cable fixation LOCTITE 352 Fix the cable terminal part with the bond Bond LOCTITE 352 Fig 12 Bonding Fig 13 Soldering Bonding VIEW A Solder leaking VIEW A VIEW...