background image

 

MINIFLEX 2-BF Instruction Manual

 

Document No. 

HIM-16031

 

 

 
 

 

10

  / 

12

 

Confidential C                                                                   

≪注意/Caution≫ 

  ・アクチュエータを解除する際、FPC 嵌合側に押さえつけないで下さい。 
    アクチュエータの破損やコンタクトの変形が発生する恐れがあります。 
    Please do not press to the direction of FPC mating side. 
    Actuator and contacts are damaged. 

 

 
 
 
 
 
 
 
 

 

図 17.  アクチュエータの解除方法  (NG) / Fig.17 To release actuator (NG) 

 

  ・アクチュエータの片端部で操作をしないで下さい。  アクチュエータが破損する恐れがあります。 
    Please do not operate side of an actuator.    Actuator is damaged. 

 
 
 
 
 
 
 

 

図 18.  アクチュエータの解除方法  (NG) / Fig.18 To release actuator (NG)

 

 
          ・ピンセット等の鋭利な工具を使用して操作しないで下さい。  コネクタを傷つける恐れがあります。 
          Please do not operate it using a sharp tool. (For example, tweezers)    Connector is damaged. 
 
 
 
 
 
 
 

 

NG 

NG 

NG 

Содержание 20617-080E-01

Страница 1: ...Inc QKE DFFDE09 03 REV 8 MINIFLEX 2 BF 0 2mm pitch FPC Conn Part No 20617 E 01 Instruction Manual 1 S19620 October 2 2019 R Morita T Masunaga H Ikari 0 S17016 January 12 2017 Y Sasa T Masunaga H Ikari...

Страница 2: ...handle our FPC connector MINIFLEX2 BF properly and safely Connector Product Name MINIFLEX 2 BF Part No 20617 E 01 part shows the number of the connector position Names of each part of the connector 1...

Страница 3: ...to the contact pressure and the reliability will not be damaged However there is the possibility that the insertion force rises in inserting FPC because the gap of contacts became narrowed Therefore p...

Страница 4: ...connector Please confirm FPC is inserted into the end of mating part fully 4 FPC OK Fig 4 FPC insertion OK Caution 5 FPC If it becomes the short insertion and oblique insertion of FPC as shown in Fig...

Страница 5: ...check of FPC insertion becomes easy by preparing the wing in FPC and preparing the silk print in board 6 FPC Fig 6 The check of FPC insertion Reference 7 FPC OK Fig 7 FPC insertion OK NG Short inserti...

Страница 6: ...housing both ends at 5N or more Housing is damaged 9 FPC NG Fig 9 FPC insertion NG FPC 5N FPC Please do not press at 5N or more FPC near a connector Contact gives damage to FPC and contact is damaged...

Страница 7: ...ator to the arrowed direction horizontally with finger cushion from the FPC inserting direction 11 OK Fig 11 To lock actuator OK Caution Please do not press an actuator from a top and lock actuator by...

Страница 8: ...ntial C Please do not operate side of an actuator Actuator is damaged or it becomes imperfect lock 13 NG Fig 13 To lock actuator NG Please do not press contact on top by finger nail etc after a lock a...

Страница 9: ...tor after a lock actuator Connector and FPC are damaged It becomes the electrical connection NG 15 NG Fig 15 To lock actuator NG Please do not operate it using a sharp tool For example tweezers Connec...

Страница 10: ...ress to the direction of FPC mating side Actuator and contacts are damaged 17 NG Fig 17 To release actuator NG Please do not operate side of an actuator Actuator is damaged 18 NG Fig 18 To release act...

Страница 11: ...the end of FPC stiffener 19 FPC OK Fig 19 Flexion of FPC OK Caution FPC FPC FPC Please avoid applying excessive stress to the FPC connector exit part FPC stiffener with FPC inserted Housing and conta...

Страница 12: ...6 Regarding board warp after mounting 90mm PCB 0 5mm JEITA ED 4702C Be careful that warp of 90mm width PCB is 0 5mm or less If excessive warp is applied Connector is damaged Reference standard JEITA E...

Отзывы: