Main Connector

4.1 Specification

4.2 Pin Assignment

4.3 Cable Recommendation

100BASE-T1 Media Converter User Manual

Rev. 1.0

01/31/18

4 / 7

Pin

Signal

Remark

1

Power

6V-28V

2

Ground

3
4
5

Data P

6

Data N

7
8

Shield

Rear View

Pin 1

Description

Vendor

Part Number Distributor

Distributor Number

Connector

MINI50 8Pos Receptacle

Molex

347910080

Digi-Key

WM9306-ND

Terminals

CTX50 Terminal L-Grip 22 AWG

Molex

5600230448

Digi-Key

WM16315CT-ND

CTX50 Terminal M-Grip 24 AWG

Molex

5600230421

Digi-Key

WM8745CT-ND

CTX50 Terminal S-Grip 26-30 AWG

Molex

5600230422

Digi-Key

WM8746CT-ND

Description

Vendor

Part Number Structure

Remark

Jacket

100BASE-T1

Dacar 547

Leoni

76D00307 2x0,13mm2

Cu, unshielded, AWG26

yes

Dacar 624

Leoni

76D00069 2x0,35mm2

Cu, unshielded, AWG22

no

Dacar 617

Leoni

76D00105 2x0,17mm2

Cu, unshielded, AWG25

no

Dacar 618

Leoni

76D00113 2x0,17mm2

Cu, unshielded, AWG25

yes

FLRY 2x0,35-B RD/BL

Leoni

2x0,35mm2

Cu, unshielded, AWG22

no

FLRY-B 1x0,35 RD

Leoni

1x0,35mm2

Cu, unshielded, AWG22

no

FLRY-B 1x0,35 BL

Leoni

1x0,35mm2

Cu, unshielded, AWG22

no

Power

Supply

Содержание 100BASE-T1

Страница 1: ...User Manual 100BASE T1 Media Converter 100BASE T1 Media Converter User Manual Rev 1 0 01 31 18 1 7...

Страница 2: ...4 5 Configuration 5 6 Software 5 6 1 User Interface 5 6 1 1 Controller Functions 6 6 1 2 100BASE T1 Functions 6 6 1 3 100BASE TX Functions 6 6 2 Firmware 6 7 Important Information 6 7 1 Packaging Ord...

Страница 3: ...J45 Mini USB Port Firmware Update Host Interface Link Activity LEDs for both LAN Ports Master Slave Role Selection via DIP Switch Automatic Master Slave Detection Software Controlled Supply Range 6V 2...

Страница 4: ...315CT ND CTX50 Terminal M Grip 24 AWG Molex 5600230421 Digi Key WM8745CT ND CTX50 Terminal S Grip 26 30 AWG Molex 5600230422 Digi Key WM8746CT ND Description Vendor Part Number Structure Remark Jacket...

Страница 5: ...user interface is mainly intended for remote monitoring but can also be used for testing and development purposes since it provides direct access to the register sets of the integrated PHYs It provide...

Страница 6: ...ion only if you do have the required knowledge The software prevents write access to certain registers which can impact the hardware configuration In auto role mode the 100BASE T1 role is set automati...

Страница 7: ...C Directive on electromagnetic compatibility and the mutual recognition of their conformity Conformity with the o a directive is confrmed by the CE mark 8 Manufacturer and Support i novative is a regi...

Отзывы: