i-milk V1 Operating Manual July 2018
13
To Clean the Milk Filter Housing
Monthly Milk Filter Cleaning
i-milk has a milk filter located on the font outlet. This black
fitting delivers a uniform, steady, non-turbulent stream of
milk. If the filter mesh becomes blocked it may cause the
milk to squirt or froth.
To remove the milk filter rotate it as you pull it down.
If debris has collected on the visible filter mesh carefully reverse flush it.
Replace the filter into the font rotating it as you push it in place and test the milk flow.
If the milk flow is still not satisfactory carry out the monthly cleaning process outlined below.
As shown in the picture below, the filter is made up of
4 stainless steel mesh filters each separated by 1 of 3
smaller “O” Rings. The must be in this sequence.
To disassemble gently push the
filters and “O” Rings out of the
filter housing into a large bowl
so as not to lose any parts.
1
black filter housing
4
identical stainless steel mesh filters
3
smaller “O” Rings that separate each mesh filter.
These drop freely into the black filter housing.
1
larger “O” ring that is inserted last. It needs to be
pushed in place as it holds the mesh assembly in
the filter housing.
Technical Adjustments
7
Содержание mini
Страница 1: ...i milk mini Operating Manual Please read thoroughly before use...
Страница 16: ...www i milk com au...