User Manual
BOP HD8 / BOP HD16
Ref.: IR1212828 A 21.08.2009
Edition 1.0
Page 59/87
I + M E A C T I A G m b H
6.4.8.
R
ELAYS
The Relays can signal events or the system state to other devices.
Default Relay Function:
Relay 1: BOP Active Relay. Close when BOP is active. Only open if BOP is out of service
Relay 2: While Recording Relay. Close while recording. Open in Pause mode.
Relay 3: BOP Active Relay. Close when BOP is active. Only open if BOP is out of service
Relay 4: Error Relay. Signals an Error according to the >General Settings<
6.4.8.1
A
UTOMATIC RELAY CONTROL
The automatic Relay control can switch the relays in a configured sequence. The sequence
will be repeated.
oxy
= Relay x shows the state y (0 .. open, 1 .. closed)
t..
= time to hold the stat of the Relay
Example of a part of a sequence
o31-t10
Relay 3 will be closed for 10 seconds.
Example of a sequence
o30-t10,o31-t10
Relay 3 will be toggled with a period of 10 seconds.
6.4.8.2
A
LARM OUTPUT
Содержание BOP HD-Reviewer Station
Страница 6: ...User Manual BOP HD8 BOP HD16 Ref IR1212828 A 21 08 2009 Edition 1 0 Page 6 87 I M E A C T I A G m b H ...
Страница 10: ...User Manual BOP HD8 BOP HD16 Ref IR1212828 A 21 08 2009 Edition 1 0 Page 10 87 I M E A C T I A G m b H ...
Страница 37: ...User Manual BOP HD8 BOP HD16 Ref IR1212828 A 21 08 2009 Edition 1 0 Page 37 87 I M E A C T I A G m b H ...
Страница 75: ...User Manual BOP HD8 BOP HD16 Ref IR1212828 A 21 08 2009 Edition 1 0 Page 75 87 I M E A C T I A G m b H ...