![I-G3N Z Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/i-g3n/z-series/z-series_reference-manual_3058192009.webp)
Power Switch
• Power switch: to turn ON/OFF the whole battery. When it is off, BMS standby, no power output.
Dry contact
• Dry contact: provided 2 ways output dry contact signal.
Address dial switch
• ADD Switch: 6 ADD switches, “0”and “1”, refer to picture right. The settings will be active only
after restart the battery.
• When the battery communicates with the inverter, the address of the battery pack must be set
to 1, and the address of the parallel slave should be greater than 1.
• When the battery Pack is connected in parallel, cascading communication is required.
Hardware address configuration is required for both the master PACK and the slave PACK,
and the hardware address can be set by the dial switch on the board. The definition of the
switch refers to the table below.
Address
Dial Switch Position
Instruction
#1
#2
#3
#4 #5
#6
1
On
Off
Off Off Off Off
use lonely main
2
Off
On
Off Off Off Off
Set as Pack 1
3
On
On
Off Off Off Off
Set as Pack 2
4
Off
Off
On Off Off Off
Set as Pack 3
5
On
Off
On Off Off Off
Set as Pack 4
6
Off
On
On Off Off Off
Set as Pack 5
7
On
On
On Off Off Off
Set as pack 6
8
Off
Off
Off On Off Off
Set as Pack 7
9
On
Off
Off On Off Off
Set as Pack 8
10
Off
On
Off On Off Off
Set as Pack 9
11
Off
Off
On On Off Off
Set as Pack10
12
Off
Off
On On Off Off
Set as Pack 11
13
On
Off
On On Off Off
Set as Pack 12
14
Off
On
On On Off Off
Set as Pack 13
15
On
On
On On Off Off
Set as Pack 14
16
Off
Off
Off Off On Off
Set as Pack 15
....
...
....
....
.... ....
....
....
62
Off
On
On On On On
63
On
On
On On On On
INTRODUCTION
7
Содержание Z Series