page 1

• All plumbing should be installed according to applicable state    

   and local codes and regulations

 

• Before installation of the I-CON sensor faucet, ensure the 

 

   lavatory/sink, drain line, and water supply line are properly 

 

   installed 

• Flush all water supply lines of any debris before making 

 

   connections

 

• Do not use pipe sealant or plumbing grease on any 

   components or couplings

Adjustable Wrench

Phillips Head 

Screwdriver

Electric Drill

with 3/16 Drill Bit

FAUCET ROUGH-IN

TOOLS NEEDED

PRIOR TO INSTALLATION

Gooseneck Sensor Faucet  (4000 Series)

Square Mid Body Sensor Faucet (4010 Series)

Round Mid Body Sensor Faucet (4005 Series)

4” Centerset  Sensor Faucet (4015 Series)

LIMITED WARRANTY

Rev 072623

I-CON Systems, Inc. (I-CON) warrants that its commercial 

manufactured products are made of first-class materials, are 

free from defects, and are made to withstand normal use when 

installed properly. Products have the following warranty periods: 

3 years for COBALT®, COBALT Pro™, and COBALT Connect™ 

faucets and flush valves and I-CON EDGE® gateways. 1 year for 

all other products and decorative finishes. The warranty period 

begins on the date of purchase. 

 

 

Defective products should be sent to I-CON at the customer’s 

expense. I-CON will take a reasonable amount of time to 

determine if the product is defective and whether it will be 

repaired or replaced. During the warranty period, items will 

either be (1) repaired at no charge using new replacement 

parts or (2) replaced with either a new similar product or one 

manufactured from new or serviceable used parts that is at 

minimum a functional equivalent to the original. The course of 

action will be determined at I-CON’s discretion. Replacement 

products that are installed according to the instructions 

provided by I-CON will assume the remaining warranty of the 

original product. The limited warranty is only applicable to 

the product’s materials and workmanship. No claims for labor, 

transportation, or other incidental or consequential costs will be 

allowed. No extended warranties are available. THE SOLE AND 

EXCLUSIVE REMEDY FOR ANY DEFECTIVE PRODUCT IS LIMITED 

TO REPAIRING OR REPLACING THE DEFECTIVE PRODUCT. Before 

installing and using products, the purchaser is responsible to 

determine the products’ suitability and assumes all risks and 

liabilities related to the product. 

 

 

This warranty only applies to persons and organizations that 

purchase I-CON products directly from I-CON or an authorized 

I-CON representative for the purpose of resale. This warranty 

does not apply to the life of batteries or other consumables.

2 18 "

54

 3 18 "

79

 

 12 14 "

311

 

 1 14 "

32

 

 75° 

  5 14 "

133

 

  8"

203

 

1
4" [6] NPSM
INLET

INSTRUCTION Drawing

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTION-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 1.75"x2"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

NON-IMPORTED (DRIVEN) AND SKETCH (INACTIVE) SET TO BLACK

INACTIVE ENTITIES SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

 3 18 "

79

 

  2"

51

 

  4 34 "

121

 

 2 14 "

57

 

 80° 

  4 34 "

121

 

1
4" [6] NPSM
INLET

INSTRUCTION Drawing

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTION-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 1.75"x2"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

NON-IMPORTED (DRIVEN) AND SKETCH (INACTIVE) SET TO BLACK

INACTIVE ENTITIES SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

 3 18 "

79

 

2 18 "

54

  6 14 "

159

 

 1 14 "

32

 

 80° 

  5 14 "

133

 

1
4" [6] NPSM
INLET

INSTRUCTION Drawing

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTION-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 1.75"x2"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

NON-IMPORTED (DRIVEN) AND SKETCH (INACTIVE) SET TO BLACK

INACTIVE ENTITIES SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

 80° 

  4 34 "

121

 

 2 12 "

64

 

1
4" [6] NPSM
INLET

 3 18 "

79

 

  4"

102

 

  6"

152

 

  4 34 "

121

 

INSTRUCTION Drawing

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-INSTRUCTION-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .002

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 1.75"x2"

CENTURY GOTHIC SIZE 5 FONT

ONE-TIME SYSTEM SETTING CHANGE

NON-IMPORTED (DRIVEN) AND SKETCH (INACTIVE) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

Содержание COBALT Essential 4000 Series

Страница 1: ...1 4 6 NPSM INLET INSTRUCTION Drawing TO CHANGE ANNOTATION SHOULD BE i consystems int Operations CAD Drawings TEMPLATES ANSI INSTRUCTION TEMPLATE sldstd SET NORMAL LINE THICKNESS TO 002 SET THIN LINE T...

Страница 2: ...i con com patents page 2 Rev 072623 FAUCET INSTALLATION SINGLE MOUNT INSTALLATION Step 1 Install the faucet through the hole in the sink with the deck seal Step 2 Slide backing plate up supply pipe an...

Страница 3: ...plate seal Step 3 Slide backing plate up supply pipe and secure with two brass nuts Ensure that faucet is facing the desired direction and that sensor cable can move freely Tighten down nuts using th...

Страница 4: ...the patent process www i con com patents page 4 Rev 072623 Step 3 Use provided screws to mount housing to wall WATER SUPPLY CONNECTIONS Water supply can be either tempered or hot cold supply TEMPERED...

Страница 5: ...ot and cold supply lines not provided to inlets of the tee or mixing valve Step 3 Attach provided 1 4 NPSM to 1 2 NPSM stainless steel braided hose between supply and inlet of control module Step 4 At...

Страница 6: ...tery cover and slide out battery holder Insert batteries according to labels on battery holder Slide battery holder back into compartment and replace battery cover AC POWERED Plug power jack into cont...

Страница 7: ...een light on the IR sensor module will blink once a second during the 5 second countdown The sensor will lock onto the target indicated by solid green light The green light will blink 3 times to confi...

Отзывы: