ENG - 19
ENG
INSTRUCTIONS FOR USE
MOUNTING
Take out the warmer and all the parts from packing carton.
1) Make the warmer be on its head
2) Place the footplate on the top of both radiation fins
3) Secure the footplate on the warmer with specified U type bolt and wing nut
4) Tighten the screw
5) Make the warmer stand erect
PLACING
The warmer should be away from the wall or other objects such as furniture, curtain at least
90 cm; do ensure that the power supply corresponds to that on the nameplate; the temperature
controller switch and power switch are at “O” position; plug in the attaching plug.
CONTROL
1)
Setting temperature
The temperature controller can regulate room temperature. Turn the temperature controller
clockwise to increase the temperature; turn it anti-clockwise to reduce the temperature until
appropriate temperature is reached.
2)
Setting power
-
Power switch is rotary switch, choose one of option:
position 1
600 W
position 2
900 W
position 3
1500 W
- The working indicator will light.
3)
Daily timer
Timer Operation
This unit has 24 hr timer which has 96 segments (T1) around
its circumference, each segment being equivalent to 15 min.
of time. With the aid of this timer it is possible to preset the
time and duration of the period(s) that it is desired the warmer
will operate, in any 24hr period. The centre of the timer has
a 3 position slide switch (T3). In the central position (denoted
by the clock symbol
) the timer will switch the warmer on
and off at times set by the segments, (see setting the timer,
below). The position denoted by the “I”, is a timer override
position. The timer will continue to run but power will be fed
continuously to the warmer. This enables the warmer to be on
all the time if required. In the position denoted by the “O”,
the timer continues to run but no power is fed to the warmer.
Setting the Timer
Ensure the slide switch on the timer is at the mid position next to the clock symbol
. Rotate
the outer ring of the timer in a clockwise direction until the current time is lined up with the arrow
pointer ▲ (T2), i.e. if the time the timer is being set is 8 pm, rotate the outer ring until
the number 20 is in line with the arrow pointer. Set the time the warmer is required to run by
pulling the segments around the outer ring forward appropriate to the running period(s) required.
When set, the warmer will operate each day during the times programmed.