J300
5
INSTRUCTION MANUAL
12.3 Function mode
Function mode list when the remote operator is used
Function mode initial values and display contents
Initial display contents, initialization, and change ranges are displayed in the table indicated below.
NOTE 1 : The motor constants R1, R2, L, M, J, Kp, Ti, and KPP vary with the capacity.
Display
sequence
(Function mode 1)
Function
No.
Function
name
(Function mode 2)
Initialization display contents
Initialization
Setting, change
contents
Setting contents
When 120Hz is switched to 400Hz
by F-30, a frequency more than
120Hz can be set.
Base
frequency
setting
1
2
3
4
5
6
F-00
F-01
F-02
F-03
Input
voltage
F-04
F-05
Motor
constant
(NOTE1)
60Hz
60Hz
0.5Hz
440
OFF
VC
NOR
NOR
Rated
capacity of
each inverter
Rated
capacity of
each inverter
Rated
capacity of
each inverter
Rated
capacity of
each inverter
4p
Maximum
frequency
setting
Start
frequency
adjustment
Motor input
voltage
setting
AVR
function for
deceleration
Control
method
setting
Autotuning
setting
Motor data
selection
Motor
capacity
setting
Motor pole
count
setting
Motor
constant R1
setting
Motor
constant R2
setting
Motor
constant L
setting
F-BASE 60Hz
F-MAX
60Hz
Fmin
0.50Hz
AVR AC
440 V
AVR DEC
OFF
CONTROL
VC
AUX AUTO
NOR
AUX DATA
NOR
AUX K
005.50 kw
AUX P
4p
AUX R1
1.004
AUX R2
0.776
AUX L
13.16 mH
30 to 120 (400)
30 to 120 (400)
0.1 to 9.9
380, 400, 415,
440, 460
ON/OFF
VC, Vp1, VP2,
Vp3, SLV, V2
NOR/AUT/NRT
NOR:Old Hitachi
general purpose
TOM:New Hitachi
general purpose
AUT:Auto-
tuning data
0.75 to 220
2, 4, 6, 8
0 to 65.535
0 to 65.535
0 to 655.35
The equipment starts running
at this set value.
The motor input voltage is set.
ON or OFF of the AVR function
for deceleration is set.
When dynamic braking torque
is necessary fir deceleration OFF
is set.
VC, Vp1, Vp2, Vp3 : V/F
characteristics SLV : Sensorless
vector control V2: Sensor vector
control
At the first running after AUT/NRT
is set, the autotuning measurement
operations executed
The autotuning motor data before
starting autotuning measurement is
data equivalent to NOR
Set capacity smaller than the rated
capacity as capacity data.
The number of poles of the motor
to be used is set.
Rated
capacity of
each inverter
Содержание J300 series
Страница 1: ......
Страница 67: ...J3005 INSTRUCTION MANUAL Unusable Monitor mode contents Contents and display Ro T option selection 99 A ...
Страница 74: ...J3005 INSTRUCTION MANUAL HHIS WZ PE 002 02 ...
Страница 88: ...J3005 INSTRUCTION MANUAL 11 STANDARD SPECIFICATIONS ...
Страница 89: ...J3005 INSTRUCTION MANUAL ...
Страница 131: ...J3005 INSTRUCTION MANUAL Appendix 5 Multi Motor Operation and Precautions for Operation ...
Страница 132: ...J3005 INSTRUCTION MANUAL ...
Страница 133: ...J3005 INSTRUCTION MANUAL ...