Condition
Possible cause/s
Corrective action/s
Indicator light ON, no AC output
Circuit breaker tripped
Reset breaker
Poor connections or broken
wire/s
Check and repair.
Broken output socket
Faulty circuit breaker
Indicator light OFF, no AC output
Generator problem
Contact dealer
Indicator light OFF, no DC output.
Circuit breaker tripped
Reset breaker
Poor connections or faulty DC
power wires
Check and repair.
Generator problem
Contact dealer
Output power available -
machine running erratically
Engine RPM set too HIGH or too
LOW
With NO LOAD for 60 hertz set at
3780 RPM
With NO LOAD for 50 hertz set at
3150 RPM.
Otherwise Contact dealer
Loose components
Locate and tighten
Internal generator problem
Contact dealer
11.
STORAGE
Long term storage of your machine will require some preventative measures to
guard against the effects of storage.
11.1.
Fuel.
11.1.1.
Drain the fuel tank, fuel tap (cock) and carburettor float bowl.
11.1.2.
Pour a cup of SAE 10W 30 motor oil inside the tank, shake the tank to line with oil.
11.1.3.
Drain off excess oil.
11.2.
Engine.
11.2.1.
Remove spark plug and pour about one table spoon of SAE10W 30 motor oil into
cylinder.
11.2.2.
With ignition switch OFF, use the recoil starter to turn the engine over several times.
11.2.3.
Replace spark plug and pull recoil until you feel compression - stop pulling at this
stage.
11.2.4.
Clean exterior of the generator and apply a rust inhibitor.
11.2.5.
Store generator in a dry well ventilated place with a cover over it.
11.2.6.
The generator must remain in a level vertical position.
Page 20
Rev 3
Содержание HY3100LE
Страница 1: ...PETROL GENERATOR Models HY3100LE HY7000LEk HY9000LEk User Manual ...
Страница 7: ...Fuel Gauge Fuel Filler Cap Unleaded Petrol 2 MACHINE LAYOUT Page 7 Rev 3 ...
Страница 8: ...Page 8 Rev 3 ...
Страница 22: ...13 WIRINGDIAGRAMS 13 1 N B Subject to change without prior notice Page 22 Rev 3 ...
Страница 25: ...Page 25 Rev 3 ...
Страница 26: ...Page 26 Rev 3 ...
Страница 27: ...Page 27 Rev 3 ...