DO NOT
make parallel connection with other generators.
7.8
DO NOT
connect an extension to the exhaust pipe.
7.9
When an extension cable is required, be sure to use a tough rubber sheathed flexible cable
(according to IEC245 or equivalent standards).
The length of the extension cable: 60m for
cable of 1.5 m m2; 1 00m for cable of 2.5mm2
7.10
Keep away from other electric cables or wires. Such as: commercial power supply lines.
8.1
In normal operating, output indicator light (GREEN) will remain on.
8.2
If the generator is overload
(over 3.0kVA),
or the connected appliance is short-circuit, the
output indicator light (GREEN) is off, and overload indicator light (RED) is on. The AC output
will be switched off, but engine is still running.
8.3
When you start the engine, it is normal that both of the Overload Indicator Light (RED) and
Output Indicator Light (GREEN) are ‘ON’ simultaneously. Overload Indicator Light will be
OFF after 5 seconds, otherwise contact you dealer.