5. GENERATOR USE
WARNING!
Be sure to ground the generator when the connected electrical
appliance is grounded.
Do not connect to the building’s electrical system. Doing so may result
in electrical shocks and fire.
To prolong engine life, do not exceed the rated running wattage. Do not
connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use a tough rubber
sheathed flexible cable (according to IEC245 or equivalent standards).
The maximum length of the extension cable: 60 meters (196 feet) for
cable of 1.5mm
2
(15.5 gauge); 100 meters (328 feet) for cable of 2.5mm
2
(13.25 gauge).
Keep away from other electric cables or wires.
5.1 OUTPUT, OVERLOAD, AND OIL ALERT INDICATOR
Light (Solid)
Description
Green
Output Indicator
ON
Indicates normal operation
OFF
Indicates a problem or unit is off
Red
Overload Indicator
ON
Indicates overload or problem with
connected appliances, disconnect any
appliances and press and hold the
reset button (1s).
OFF
Indicates normal operation
Red
Low Oil Indicator
ON
Indicates insufficient oil in the
crankcase
OFF
Indicates normal operation