RF Data Modem HWC-M100 / HWC-W100 / HWC-W120
17
∎
In AP-mode, you need to set Net-ID, Device-ID, AP/EP-Mode as follows:
- NET-ID : Network Number. Each network has its own unique frequency band.
and you can select one of the 16 network.(Net.ID : 0~15)
- DEVICE-ID : Device-ID of the AP. Each AP has its own unique number in a network.
and you can select one of the 20 APs.(Device-ID : 0~19)
- AP/EP-Mode : You must turn the dip-switch for AP/EP-mode to ON.
∎
In AP-Mode, RF-Modem communicate with RF-Master through Ethernet. Its network
parameter(IP-address, subnet-mask, gateway, MAC-address) is automatically configured by
Device-ID because it is operated in private network.
ex.1) In AP Mode, Device-ID is 3.
Device ID : 3
IP Address : 192.168.10.53(Device-ID + 50)
Subnet Mask : 255.255.255.0
Gateway : 192.168.10.254
MAC Address : 00:0A:1F:00:EC:35(Device-ID + 50)
ex.2) In EP Mode, Device ID is 3
Device ID : 3
IP Address : 192.168.10.103(Device ID + 100)
Subnet Mask : 255.255.255.0
Gateway : 192.168.10.254
MAC Address : 00:0A:1F:00:EC:67(Device ID + 100)
Содержание HWC-M100
Страница 1: ...RF Data Modem HWC M100 HWC W100 HWC W120 User Manual...
Страница 6: ...RF Data Modem HWC M100 HWC W100 HWC W120 4 1 3 Product Description RF Master HWC M100...
Страница 8: ...RF Data Modem HWC M100 HWC W100 HWC W120 6 RF Modem HWC W100...
Страница 10: ...RF Data Modem HWC M100 HWC W100 HWC W120 8 RF Modem HWC W120...
Страница 12: ...RF Data Modem HWC M100 HWC W100 HWC W120 10 2 Installation the device 2 1 Network configuration...
Страница 20: ...RF Data Modem HWC M100 HWC W100 HWC W120 18 AP Information Window in GUI EP Information Window in GUI...
Страница 38: ...RF Data Modem HWC M100 HWC W100 HWC W120 36 6 Dimension 6 1 RF Master HWC M100 TOP VIEW FRONT VIEW REAR VIEW...
Страница 39: ...RF Data Modem HWC M100 HWC W100 HWC W120 37 6 2 RF Modem HWC W100 TOP VIEW FRONT VIEW REAR VIEW...
Страница 40: ...RF Data Modem HWC M100 HWC W100 HWC W120 38 6 3 RF Modem HWC W120 TOP VIEW FRONT VIEW REAR VIEW...