13
2.1 Compressor delay protection
The compressor is ceased for 3 minutes to balance the pressure in the
refrigeration cycle in order to protect the compressor.(This protection include the
Cooling or the exchange Dry and Heat mode, but the unit has no this function after
it restored. If the unit restored and turn ON, then this protection would be
functioned.)
2.2 Fan motor(PG motor) protection
When the Fan motor(PG motor) receive the signal, it will be stopped after it
detected the speed less than 200RPM, at the same time, the error code, “E4”, will
be displayed.
3. Control panel and display
3.1 Digital Tube display(
)
3.2 Filter Monitor button(emergency button) : (
)
The operation mode, air volume and temperature setting will recovery as the last
time setting when press the emergency button in the stand-by state. If the appliance
connects to power source and the Emergency button press, it will operate in the
Auto–mode, if the Emergency button select again, the appliance will turn in stand-by
sate.
When the digital tube display “FC” after 240 hours of usage as reminder to