8
CAUTION
Pre-operation checks should be carried out each time the generator is used.
WARNING
All fuels are flammable
ALWAYS
fuel and defuel in a well ventilated area outside of buildings.
ALWAYS
wear the correct Personal Protective Equipment (PPE) when handling
fuels.
2.0
Fuel
2.1
Check the fuel level via the fuel filler cap.
2.2
If the fuel level is low, refill with fresh unleaded petrol.
2.3
Make sure you use the fuel filter screen on the fuel filler neck.
Model Number
Capacity
HY8500
6.0 Litres
HY10000
6.0 Litres
HY220DC
6.0 Litres
2.4
Check engine oil
2.5
Before checking the engine oil, make sure the generator is put on stable, level
ground.
2.6
Remove the oil filler cap and check engine oil level.
2.7
If the oil level is below the lower level line, refill with 15w40 oil to the upper level.
N.B.
do not screw the filler cap on when checking oil level.
2.8
Change contaminated oil.
2.9
Oil capacity.
Model Number
Capacity
HY8500
1100ml
HY10000
1100ml
HY220DC
1100ml
2.10
Earthing (Ground)
2.11
This generator is supplied with a ‘floating earth’.
2.12
It is therefore extremely important that you only use the generator to power
equipment in the following permutations;
1 or more Class 2 equipment or,
1 piece of Class 1 equipment or,
1 or more Class 2 equipment and 1 piece of Class 1 equipment.
2.13
Class 1 equipment uses an earth wire.
2. PRE-OPERATION CHECKS
Содержание Hirepro HY10000