21
HHD
SERIES
3.4 Electric Start Battery Connection (HHD7250 ONLY)
Batteries product explosive gases. Keep sparks, flames and cigarettes
away from the battery at all times. To prevent the possibility of creating
a spark while using the battery, connect charging cables to battery
terminals first, then to the generator. When disconnecting, disconnect
the cables at the generator first.
1.
Connect the red cable with the positive terminal of the battery. Ensure the
connection is secured by using the fastener at the battery terminal.
2.
Connect the black cable with the negative terminal of the battery. Ensure the
connection is secured by using the fastener at the battery terminal.
Be sure to connect the Electric Start Battery to the generator set before
operation. Failure to do so will cause the output display to function
improperly.
Do not reverse the polarity of the terminals when charging the battery.
Serious damage to the generator and/or battery may occur. Do not
attempt to connect the battery while the generator engine is running.
Disconnect the cables from the battery while the generator is in storage.
Filter Cap
Filter
Knobs
Negative terminal
(Black)
Positive Terminal
(Red)
Содержание HHD SERIES
Страница 1: ...HHD SERIES USER GUIDE ...
Страница 4: ...THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM ...
Страница 13: ...13 HHD SERIES FUEL ON OFF CHOKE OPEN CLOSED HHD7250 only 2 1 Label Placement ...
Страница 14: ...14 ...
Страница 34: ...34 Chapter 8 Wiring Diagram HHD3500 ...
Страница 35: ...35 HHD SERIES Wiring Diagram HHD6250 ...
Страница 36: ...36 Wiring Diagram HHD7250 ...
Страница 40: ...40 ...
Страница 42: ...42 ...
Страница 44: ...44 ...
Страница 45: ...45 HHD SERIES Enjoy Be sure to check www hyundaipower ca for updates regarding your generator ...