Hyundai HE-DX330 Скачать руководство пользователя страница 3

2) Read and comply with all caution and safety related 

notes non or inside the cabinet, or on the chassis. 

 
3) Design Alteration Warning-Do not alter of add to the 

mechanical or electrical design of this instrument. 
Design alterations and additions, including but not 
limited to, circuit modifications and the addition of 
items such as auxiliary audio output connections, 
might alter the safety characteristics of this instrument 
and create a hazard to the user. Any design alterations 
or additions will make you, the service, responsible 
for personal injury or property damage resulting there 
from. 

 
4) Observe original lead dress. Take extra care to assure 

correct lead dress in the following areas:   
(1) near sharp edges, (2) near thermally hot parts (be 
sure that leads and components do not touch 
thermally hot parts), (3) the AC supply, (4) high 
voltage, and (5) antenna wiring. Always inspect in all 
areas for pinched, out-of-place, or frayed wiring. Do 
not change spacing between a component and the 
printed-circuit board, Check the AC power cord for 
damage. 

 

5) Components, parts, and/or wiring that appear to have 

overheated or that are otherwise damaged should be 
replaced with components, parts and/or wiring that 
meet original specifications. Additionally determine 
the cause of overheating and/or damage and, if 
necessary, take corrective action to remove and 
potential safety hazard. 

 
6) Product Safety Notice-Some electrical and mechanical 

parts have special safety-related characteristics which 
are often not evident from visual inspection, nor can 
the protection they give necessarily be obtained by 
replacing them with components rated for higher 
voltage, wattage, etc. Parts that have special safety 
characteristics are identified by shading, an (

) or a 

(

) on schematics and parts lists. Use of a substitute 

replacement that does not have the same safety 
characteristics as the recommended replacement part 
might created shock, fire and/or other hazards. 
Product safety is under review continuously and new 
instructions are issued whenever appropriate. 

 
 

 
 

1-2 Servicing Precautions 

CAUTION: 

Before servicing Instruments covered by this 

service manual and its supplements, read and follow the 
Safety Precautions section of this manual. 
 

Note: 

If unforeseen circument create conflict between the 

following servicing precautions and any of the safety 
precautions, always follow the safety precautions. 
Remember; Safety First 
 

1-2-1 General Serving Precautions 

(1) a. Always unplug the instrument’s AC power cord from 

the AC power source before (1) removing or 
reinstalling any component, circuit board, module or 
any other instrument assembly. (2) disconnecting 
any instrument electrical plug or other electrical 
connection. (3) connecting a test substitute in 
parallel with an electrolytic capacitor in the 
instrument. 

b. Do not defeat any plug/socket B+ voltage interlocks 

with which instruments covered by this service 
manual might be equipped. 

c. Do not apply AC power to this instrument and/or any 

of its electrical assemblies unless all solid-state 
device heat sinks are correctly installed. 

d. Always connect a test instrument’s ground lead to 

the instrument chassis ground before connecting the 
test instrument positive lead. Always remove the test 
instrument ground lead last. 

Note:

 Refer to the Safety Precautions section ground 

lead last. 

(2) The service precautions are indicated or printed on the 

cabinet, chassis or components. When servicing, 
follow the printed or indicated service precautions 
and service materials. 

(3) The components used in the unit have a specified flame 

resistance and dielectric strength. 
When replacing components, use components which 
have the same ratings, by (

) or by (

) in the 

circuit diagram are important for safety or for the 
characteristics of the unit. Always replace them with 
the exact replacement components. 

(4) An insulation tube or tape is sometimes used and some 

components are raised above the printed wiring board 
for safety. The internal wiring is sometimes clamped 

 

Содержание HE-DX330

Страница 1: ...MT1389DE E SOLUTION MODEL HE DX330 ...

Страница 2: ... or a metering system that complies with American National Standards institute ANSI C101 1 Leakage Current for Appliances and underwriters Laboratories UL 1270 40 7 With the instrument s AC switch first in the ON position and then in the OFF position measure from a known earth ground metal water pipe conduit etc to all exposed metal parts of the instrument antennas handle brackets metal cabinets s...

Страница 3: ... part might created shock fire and or other hazards Product safety is under review continuously and new instructions are issued whenever appropriate 1 2 Servicing Precautions CAUTION Before servicing Instruments covered by this service manual and its supplements read and follow the Safety Precautions section of this manual Note If unforeseen circument create conflict between the following servicin...

Страница 4: ... Alternatively obtain and wear a commercially available discharging wrist strap device which should be removed for potential shock reasons prior to applying power to the unit under test 2 after removing an electrical assembly equipped with ESD devices place the assembly on a conductive surface such as aluminum foil to prevent electrostatic charge buildup or exposure of the assembly 3 Use only a gr...

Страница 5: ...ent Descriptions 2 1 1 DVD SANYO HD65 Connector Pin Definition I F Signals I O Pin F 1 F 2 T 3 T 4 C 5 D 6 CD DVD 7 RF 8 A 9 B 10 F 11 GND PD 12 VC 13 VCC 14 E 15 NC 16 VR CD 17 VR DVD 18 LD CD 19 MD 20 HFM 21 NC 22 LD DVD 23 GND LD 24 ...

Страница 6: ...lator Error Correction PLI Focus Tracking SDRAM 4 16M I F Control frant pannel Loading Motor Focus Coil Track Coil Sled Motor Spindle Motor CD5888 5ch motor Drive 80c52 System Controller Flash Memory 8Mbit Disc Laser pickup Disc motor unit Spindle motor single for CLV ...

Страница 7: ... 1 2 DVD Processor Chip MT1389DE E 2 Pinout Diagram ...

Страница 8: ...chmitt Trigger Filtered Inputs for Noise Suppression z Bi directional Data Transfer Protocol z 100 kHz 1 8v 2 5V 2 7V and 400 kHz 5V Compatibility z Write Protect Pin for Hardware Data Protection z 16 Byte Page 8K 16K Write Modes z Partial Page Writes Are Allowed z Self Timed Write Cycle 10 ms max z High Reliability Endurance 1 Million Write Cycles Data Retention 100 Years ESD Protection 3000V z A...

Страница 9: ...2 1 4 8M BIT 1M 8 512Kx16 CMOS FLASH MEMORY ...

Страница 10: ......

Страница 11: ...2 1 5 1M X 16 Bit X 4 Banks Synchronous DRAM ...

Страница 12: ......

Страница 13: ...2 1 6 5 channel drivers IC AM5888 ...

Страница 14: ......

Страница 15: ...2 1 7 Dual Operational Amplifier MC4558 ...

Страница 16: ...2 1 8 LED driver IC SC6928 TM1628 ...

Страница 17: ......

Страница 18: ......

Страница 19: ...2 1 9 Power Supply Switch IC FSDM311 ...

Страница 20: ......

Страница 21: ...udio Performance Frequency Response DVD fs 48 96KHz 4Hz 22 44KHz Video CD fs 44 1KHz 4Hz 20KHz Audio CD fs 44 1KHz 4Hz 20KHz D A Converter 192KHz 24bit S N Ratio 90dB Analog audio output 1 2 0V RMS Coaxial audio output 0 5V pk to pk 75Ω Connections Coaxial digital out X1 Audio Analog out for 2 channel X1 5 1CH audio output X1 Composite video output X1 Component output X1 SCART output X1 S Video ou...

Страница 22: ...DVD player a menu will appear on the screen at the beginning Upgrade File Detected Upgrade Press Play To Start If OPEN key is pressed at this time the upgrade process will be canceled 4 Press Play Key to start upgrade press and the screen will display the following messages Upgrading Upgrade File Detected Upgrade Press Play To Start 5 Waiting till the player restarting Notice Do not shut down the ...

Страница 23: ...ted into the appropriate jack Please change the audio cable with a new one if the cable is damaged If the unit has been played in Slow or Pause mode press Play to return to the normal playback mode If the unit is played in X2 X4 X8 mode press Play to return to the normal playback speed mode When the unit is in System Setting Menu Program Menu press Setup PROGRAM to exit the system Menu program men...

Страница 24: ...om the beginning Because the play mode is in the Program Random Repeat or Repeat A B mode Press these relative functions again to restore the play mode Please refer to the Advanced Operations Chapter While the DVD Title Chapter or DVD Setup menu is displayed on the TV screen directly or while playing Video CD that includes PBC function the Setup menu is displayed on the TV screen Stop playing auto...

Страница 25: ...6 Disassembly and Reassembly ...

Страница 26: ...7 Block Diagram ...

Страница 27: ...8 Circuit Diagram MPEG BOARD ...

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ... POWER SUPPLY BOARD ...

Страница 32: ......

Отзывы: