7-72
Charger TRIP is occurred after abnormality lamp is on.
In case error code is "O.C"
Ą
Ą
Output over current, established as 120% of the rated
current.
Κ
In-
crease
De-
crease
Re-establish the charging current
volume in the center of PCB as turning
it anti clockwise rotation
Measure
the output current by
DC current measure
AH
÷
8
NO
YES
Re-establish or release the
output over-current volume
"9/OC" on the lower left side
of PCB as turning it anti
clockwise rotation
Restart the charger as pushing
reset switch in the monitor.
Measure
the output current
by DC current
measure
Decrease
Increase
YES
Change
PCB
NO
After RESET
Check charger
NO
Change
PCB
OK
OK
YES