![Hyundai 15P-7 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/hyundai/15p-7/15p-7_manual_2197447032.webp)
4-5
Charger
BATTERY CHARGER
SWITCH
MANUAL STOP
CHARGE LEVEL
RESET
EQUAL S/W
ERROR
END
EQUAL
FLOAT
AC IN
BATTERY CHARGER MONITOR
NOTICES
Charge the battery through removing the
battery connector and connecting the
charging connector of the stationary
charger to the battery connector.
BP157OM21
6)
(1)
Battery
cover
Be sure to open the battery cover during
charging.
BP157OM22
(2)
-10
10 20 30 40 50
St
1,300
1,250
1,200
1,150
S20
1,300
1,250
1,200
1,150
t( C)
Check specific gravity and electrolyte level
once a week. Specific gravity at a
temperature of 20
Á
C is as follows :
At charged(completion of charge) : 1.280
At discharged(Charging required) : 1.17
BP157OM23
(3)
Red color float support
Red color ring
Float
Normal level
Check electrolyte level, and if it is
insufficient, refill distilled water to the
specified level.
Distilled water should be refilled to get the
red color ring the stopper or come the red
color float support out.
BP157OM24
(4)