Hyundai power products HYSP850D Скачать руководство пользователя страница 9

 

 

 

 

 

NOTE

 

 

 

Attach a sufficiently long and strong rope to the handle before first use. 

 

 

The pump is submerged into the liquid by using the rope. 

 

 

In case of continuous use of the pump with the rope, the condition of the rope must  

 

 

be checked regularly.

 

 

 

NOTE

 

 

 

DO NOT

 allow the pump to run dry.

 

NOTE

 

The pump must be checked for damage before operation. 
The liquid being pumped will become contaminated if this pump becomes damaged and 
lubricant within the pump escapes.

 

 

                  MAXIMUM SOLIDS DIAMETER: 35mm

 

 

 

 
3.0 

 

Screw the elbow into the outlet on the pump body. 

3.1 

 

Connect the required diameter pump outlet hose adapter. 

3.2 

 

Connect the hose (not supplied) to the pump outlet adapter. 

 

 

NOTE

: Reducing the hose diameter will affect the maximum flow rate.

 

 

 

3.3 

 

Adjust the depth of the float switch to the desired depth by clipping the float switch  

 

 

cable into the float switch depth clip at the desired level. 

3.4 

 

Insert the pump into the liquid at a 45° angle to help remove as much air as possible. 

3.5 

 

If there is any debris or sediment in the liquid, the pump should be placed vertically 

 

 

on a platform, bricks or similar. 

3.6 

 

You must place the pump so there is adequate space for the float switch to operate 

 

 

without obstruction. 

3.7 

 

Always raise or lower the pump using a suitable rope attached to the carrying handle 

 

 

and not by the mains or float switch cable. 

 

 

3.8 

 

Connect the pump to the mains. 

 

 

Always use a high sensitivity Residual Current Device (RCD) with a tripping current 

 

 

of less than 30mA. 

3.9 

 

Turn the mains supply on. 

        3. OPERATING INSTRUCTIONS 

        

ASSEMBLY

 

        

SETTING UP THE PUMP

 

        

USING THE PUMP

 

Содержание HYSP850D

Страница 1: ...1...

Страница 2: ...7 2 PART LOCATIONS 8 3 OPERATING INSTRUCTIONS 9 10 4 MAINTENANCE 10 5 TROUBLESHOOTING 11 6 SPECIFICATION 12 7 DECLARATION OF CONFORMITY 13 8 PRODUCT DISPOSAL RECYCLING 14 9 CONTAT DETAILS 15 10 WARRAN...

Страница 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Страница 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Страница 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Страница 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Страница 7: ...ormity 1 80 General Machine Safety 1 81 Do not use the pump if damaged 1 82 You must always inspect the pump cables and plug for damage before use 1 83 Disconnect the pump from the mains power supply...

Страница 8: ...8 1 Carrying Handle 2 Pump Body 3 Pump Outlet 4 Pump Base 5 Float Switch 6 Float Switch Level Clip 2 PART LOCATIONS...

Страница 9: ...diameter will affect the maximum flow rate 3 3 Adjust the depth of the float switch to the desired depth by clipping the float switch cable into the float switch depth clip at the desired level 3 4 I...

Страница 10: ...ins and float switch cable for wear or damage 4 2 Remove any obstructions from the base of the pump and impeller 4 3 Rinse the exterior of the pump with clean water 4 4 Remove stubborn contamination w...

Страница 11: ...ked inlet Check the inlet and remove obstruction Blocked outlet Check the outlet and remove obstruction Exceeded maximum pump head Check the specifications for maximum head Air trapped inside the pump...

Страница 12: ...850D Voltage v 230v 50Hz Power w 850 Max Flow Rate l h 17500 Head m 10 Max Depth m 7 Outlet Hose Size Inlet Diameter 33 40 50 60mm Max Solid Diameter mm 35 Max Water Temperature C 35 Weight kg 6 5 6 S...

Страница 13: ...Pump Net installed power 850w The technical documentation is kept by Roland Llewellin Genpower Ltd Isaac Way Pembroke Dock Pembrokeshire SA72 4RW The conformity assessment procedure followed was in ac...

Страница 14: ...uthority or recycling centre 8 4 Certain products contain batteries which should not be disposed of in your domestic waste 8 5 You MUST recycle batteries which should not be disposed of in your domest...

Страница 15: ...re constantly being reviewed and updated However if you find an error omission or something you find unclear please contact your dealer for assistance 11 1 Our latest manuals are also placed online 9...

Страница 16: ...mbroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by GENPOWER LTD for The United Kingdom...

Отзывы: