Hytronik HMW11 Скачать руководство пользователя страница 2

Ceiling mounted detection pattern (m)

Ceiling mounted height(m)

6

0

12

10%

10%

30%

30%

75%

75%

50%

50%

5. Wiring Diagram

Description of the 
Button Functions 
(remote control HRC-11)

7. 

HRC-11

6

8

10

11

12

13

14

2

4

1

3

7

9

5

Permanent ON/OFF [               ]

Press button      to select permanent ON or permanent OFF mode.
 * Press button     /     to resume automatic operation.
The mode will change to AUTO Mode after power failure.   

Semi-auto Mode [ button     &     ]

Power output [ button 

   

 ]

Press button     , the light output shifts between 80% and 100%.
Note: the function of “Sensor off” and “Twilight” are disabled.          

Ambient daylight threshold [ button 

    

 ]

Detection range [ zone     ] 

Press buttons in zone 

   

  to set detection range at 100% / 75% / 

50% / 10%.

Stand-by time [ zone     ]

Press buttons in zone     to set the stand-by period at 0s / 10s / 
1min / 5min / 10min / 30min / 1h / +∞. 
Note: “0s” means on/off control; “+∞” means bi-level control, 100% 
on when motion detected, and remains at the stand-by dimming 
level when no presence after hold-time.

Daylight threshold [ zone 

   

  ]          

Press buttons in zone     to set the daylight sensor at 2Lux / 10Lux / 
50Lux / 100Lux / 300Lux / 500Lux or Disable.
Note: To set daylight sensor at 100Lux / 300 Lux / 500Lux, press 
         button     Shift at first.

button 

Auto Mode [ button     ]

Brig/- [ button     ]

Press button     to adjust the light brightness between 10%~100% . 

Scene prog. [ zone      ] (One-key-commissioning)

1. Press button     Shift, the red LED is on for indication. 
2. Press button 

    

, the ambient lux level is sampled and set as the 

    new daylight threshold.

Hold time [ zone     ]

Press buttons in zone     to set the hold time at 2s / 30s / 1min / 
5min / 10min / 15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button 
                Shift at first.
         2. 2s is for test purpose only, stand-by period and daylight     
             sensor settings are disabled in this mode.
*To exit from Test mode, press button     or any button in zone     .    

Stand-by dimming level [ zone      ]

Press buttons in zone     to set the stand-by dimming level at 10% / 
20% / 30% / 50%.

 Dual tech & RF mode [ zone     ]

 All buttons in zone      are disabled. 

Detection Pattern

6. 

Shift [ button 

    

 ]

LED Driver

1-10V

+
-

L

N

P

L
N

1-10V

+

-

L’ N N L

RESET [ button     ]

Press button     , all settings go back to the rotary switch settings.

Press button     to initiate automatic mode. The sensor starts working
and all settings remain as before the light was switched ON/OFF.

1. Press button “Start” to program.
2. Select the buttons in      “Detection range”,     /     “Daylight threshold”, 
        “Hold time”,      “Stand-by time”,      “Stand-by dimming level” to   
    set all parameters.
3. Press button “Memory” to save all the settings programmed in the 
    remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).     
    For example, to pre-set detection range 100%, daylight threshold
    Disable, hold time 5min, stand-by time +∞, stand-by dimming level 
    30%, steps should be:
    Press button     Start, button     100%,     Disable,     Shift,     5min,        
         Shift,     +∞ ,     30%,     Memory. By pointing to the sensor unit(s)   
    and pressing      Apply, all settings are passed on the sensor(s).

Press button     , the LED on the top left corner is on for indication.    
All values / settings in RED are in valid for 20 seconds. 

1. Press button     Shift (the red LED is on for indication), 
2. press button     to initiate semi-auto mode. The fixture is manually on 
    by push-switch and automatically off in semi-auto mode.

1

8

3

3

2

9

10

11

12

13

14

14

13

12

11

11

10

9

8

2

2

3

3

3

3

4

4

4

5

6

7

7

7

7

3

3

8

8

9 10

10

11

13

12

11

12

13

6

5

4

1

2

4

3

HMW11-20180809-A1

The motion sensor is employed, but only activated on the manual press of the push switch, 
The light remains on during presence and dims down in absence, eventually switching off 
automatically after the stand-by time has expired.
Note: in this mode, the push terminal used for the ‘manual on’ switch input. 
         End-user can choose either function 4.3 or 4.4 for application. Default function is 4.3.

4.4 Semi-auto Function (Absence Detection)

4.3 Manual Override

With the help of push-switch, this sensor maybe over-ridden by the end-users to switch on/off 
the lights manually, or adjust the light brightness during motion hold-time. This makes the 
product more user-friendly and offers more options to fit for extra-ordinary demands.
* Short push (<1s): on/off function;
  ON 

 OFF: the light turns off immediately and cannot be lighten for a certain time (equals 

to hold time preset) even there is movement is detected. After this period, the sensor goes 
back to auto sensor mode.
  OFF 

 ON: the light turns on 100% and goes to auto sensor mode, even when ambient 

                     Lux level exceeds the daylight threshold.
* Long push (>1s): adjust the maximum brightness (between 10% and 100%) during 
                             hold-time. Both the settings on remote control and push switch can 
                             overwrite each other, the last adjustment remains in memory. 

HMW11

Hytronik Industrial Ltd.  |  www.hytronik.com
3rd Floor, block C, complex building, 155#, Bai'gang road south, 
Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
Tel: 86-752-2772020   Fax: 86-752-2777877  

Note: if neither function 4.3 nor 4.4 is desired, simply leave the “push” terminal disconnected.

& A

4

4h

h

h

Note:the function of 24h /12h /4h /30s are disabled.

Отзывы: