9. Trouble Shooting

Description of the 
Button Functions 
(remote control HRC-11)

MALFUNCTION CAUSE REMEDY

CAUSE

REMEDY

The fixture does not light up

The fixture is always on

Check detection area setting

The fixture is on when it should not

Incorrect daylight threshold setting

Continued movement in the detection zone 

Sudden change in temperature due to weather (wind, rain, snow) or air 

expelled from fans, open windows

Detection zone not targeted

Faulty fixture

No power supply

Adjust daylight threshold setting

Replace fixture

Check power to sensor

Check detection area setting

Adjust zone, change installation site

8. 

HRC-11

6

8

10

11

12

13

14

2

4

1

3

7

9

5

Ambient daylight threshold [ button 

    

 ]

Detection range [ zone     ] 

Press buttons in zone 

   

  to set detection range at 100% / 75% / 

50% / 10%.

Stand-by time [ zone     ]

Press buttons in zone     to set the stand-by period at 0s / 10s / 
1min / 5min / 10min / 30min / 1h / +∞. 
Note: “0s” means on/off control; “+∞” means bi-level control, 100% 
on when motion detected, and remains at the stand-by dimming 
level when no presence after hold-time.

Daylight threshold [ zone 

   

  ]          

Press buttons in zone     to set the daylight sensor at 2Lux / 10Lux / 
50Lux or Disable.
Note: 100Lux / 300 Lux / 500Lux are disabled.

1. Press button     Shift, the red LED is on for indication. 
2. Press button 

    

, the ambient lux level is sampled and set as the 

    new daylight threshold.

Hold time [ zone     ]

Press buttons in zone     to set the hold time at 2s / 30s / 1min / 
5min / 10min / 15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press 
            button     Shift at first.
         2. 2s is for test purpose only, stand-by period and daylight     
             sensor settings are disabled in this mode.
 *To exit from Test mode, press button     or any button in zone     .

Stand-by dimming level [ zone      ]

Press buttons in zone     to set the stand-by dimming level at 10% / 
20% / 30% / 50%.

 Dual tech & RF mode [ zone     ]

 All buttons in zone      are disabled. 

8

3

3

9

10

11

12

13

14

14

13

12

11

11

10

9

8

Permanent ON/OFF [                ]

Press button     , to select permanent ON or permanent OFF mode.
* Press button     /      to resume automatic operation. 

Power output [ button 

   

 ]

All buttons in zone     are disabled.        

button 

Auto Mode [ button     ]

Brig/- [ button     ]

All buttons in zone      are disabled. 

Scene prog. [ zone      ] (One-key-commissioning)

Shift [ button 

    

 ]

RESET[ button     ]

Press button     , all settings go back to the rotary switch settings.

Press button     to initiate automatic mode.The sensor starts working
and all settings remain as before the light was switched ON/OFF.
Note: the function of Semi-auto is disabled.

1. Press button “Start” to program.
2. Select the buttons in      “Detection range”,     /     “Daylight threshold”, 
        “Hold time”,      “Stand-by time”,      “Stand-by dimming level” to   
    set all parameters.
3. Press button “Memory” to save all the settings programmed in the 
    remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).     
    For example, to pre-set detection range 100%, daylight threshold
    Disable, hold time 5min, stand-by time +∞, stand-by dimming level 
    30%, steps should be:
    Press button     Start, button     100%,     Disable,     Shift,     5min,        
         Shift,     +∞,      30%,     Memory. By pointing to the sensor unit(s)   
    and pressing      Apply, all settings are passed on the sensor(s).

Press button     , the LED on the top left corner is on for indication.    
All values / settings in RED are in valid for 20 seconds. 

1

2

2

3

3

4

4

5

6

7

7

7

7

3

3

8

8

9

10

10

11

13

12

11

12

13

6

5

1

2

4

2

6. Wiring Diagram

Detection Pattern

7. 

walking across 10m

walking towards 8m

L

N

DALI power 
supply

DALI

 driver

Bus-mastering

DALI master

DALI

 driver

DA1 DA2

DA1 DA2

HIR23-20160912-A2

HIR23

HIR23

Отзывы: