Description of the
Button Functions
(remote control HRC-11)
8.
HRC-11
6
8
10
11
12
13
14
2
4
1
3
7
9
5
Detection Pattern
7.
HIM11-20190104-A1
6.2 Manual Override / Push Function (Default)
With the help of push-switch, this sensor maybe over-ridden by the end-users to switch on/off the
lights manually, or adjust the light brightness during motion hold-time. This makes the product
more user-friendly and offers more options to fit for extra-ordinary demands.
* Short push (<1s): on/off function;
ON
→
OFF: the light turns off immediately and cannot be lighten for a certain time (equals to
hold time preset) even movement is detected. After this period, the sensor goes
back to auto sensor mode.
6.3 Semi-auto Function / Absence Detection (Optional)
The motion sensor is employed, but only activated on the manual press of the push switch. The
light remains on during presence and dims down in absence, eventually switching off automatically
after the stand-by time has expired.
Note: in this mode, the push terminal used for the ‘manual on’ switch input. End-user can choose
either function 5.2 or 5.3 for application. Default function is 5.2.
6. Functions
Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas require
a light change notice before switch-off.
It offers 3 levels of light: 100%-->dimmed light-->off; and 2 periods of selectable waiting time: motion
hold-time and stand-by time; Selectable daylight threshold and detection area.
6.1 Tri-level Control (Corridor Function)
6.4 Lux Off Function
The built-in daylight sensor can measure ambient natural light and switch off the fixture automatically
whenever artificial light is not required (natural light lux level exceeds daylight threshold).
Note: if the stand-by time is preset at "+∞", the fixture never switches off even when natural light
is sufficient.
Permanent ON/OFF [ ]
Press button to select permanent ON or permanent OFF mode.
* Press button / to resume automatic operation.
The mode will change to AUTO Mode after power failure.
Semi-auto Mode [ button & ]
Power output [ button
]
Press button , the light output shifts between 80% and 100%.
Note: the function of “Sensor off” and “Twilight” are disabled.
button
Auto Mode [ button ]
Brig/- [ button ]
Press button to adjust the light brightness between 10% ~ 100%.
Scene prog. [ zone ] (One-key-commissioning)
Shift [ button
]
RESET [ button ]
Press button , all settings go back to the rotary switch settings.
Sensor mode return to DIP switch settings.
Press button to initiate automatic mode. The sensor starts working
and all settings remain as before the light was switched ON/OFF.
1. Press button “Start” to program.
2. Select the buttons in “Detection range”, / “Daylight threshold”,
“Hold time”, “Stand-by time”, “Stand-by dimming level” to
set all parameters.
3. Press button “Memory” to save all the settings programmed in the
remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).
For example, to pre-set detection range 100%, daylight threshold
Disable, hold time 5min, stand-by time +∞, stand-by dimming level
30%, steps should be:
Press button Start, button 100%, Disable, Shift, 5min,
Shift, +∞ , 30%, Memory. By pointing to the sensor unit(s)
and pressing Apply, all settings are passed on the sensor(s).
Press button , the LED on the top left corner flashes for indication.
All values / settings in RED are in valid for 20 seconds.
1. Press button Shift (the red LED flashes for indication),
2. press button to initiate semi-auto mode. The fixture is manually on
by push-switch and automatically off in this mode.
1
2
2
3
3
3
3
4
4
4
5
6
7
7
7
7
3
3
8
8
9 10
10
11
13
12
11
12
13
6
5
4
1
2
4
Ambient daylight threshold [ button
]
Detection range [ zone ]
Press buttons in zone
to set HF detection range at 100% / 75% /
50% / 10%.
Stand-by time [ zone ]
Press buttons in zone to set the stand-by time at 0s / 10s / 1min /
5min / 10min / 30min / 1h / +∞.
Note: “0s” means on/off control; “+∞” means bi-level control, 100%
on when motion detected, and remains at the stand-by
dimming level when no presence after hold-time.
Daylight threshold [ zone
]
Press buttons in zone to set the daylight sensor at 2Lux / 10Lux /
50Lux / 100Lux / 300Lux / 500Lux or Disable.
Note: To set daylight sensor at 100Lux / 300 Lux / 500Lux, press
button Shift at first.
1. Press button Shift, the red LED flashes for indication.
2. Press button
, the ambient lux level is sampled and set as the
new daylight threshold.
Hold time [ zone ]
Press buttons in zone to set the hold time at 2s / 30s / 1min /
5min / 10min / 15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button
Shift at first.
2. 2s is for test purpose only, stand-by time and daylight
sensor settings are disabled in this mode.
* To exit from Test mode, press button or any button in zone .
Stand-by dimming level [ zone ]
Press buttons in zone to set the stand-by dimming level at 10% /
20% / 30% / 50%.
Dual tech & RF mode [ zone ]
1. Press buttons in zone to select sensor technology.
HF+PIR: Light is on when both HF and PIR sensors are activated.
HF/PIR: Light is on when HF or PIR sensors are activated.
2. Learn / Erase, Transmit, RX100% and RX STBY% are disabled.
8
3
3
2
9
10
11
12
13
14
14
13
12
11
11
10
9
8
3
Hytronik Industrial Ltd. | www.hytronik.com
3rd Floor, block C, complex building, 155#, Bai'gang road south,
Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
Tel: 86-752-2772020 Fax: 86-752-2777877
* Long push (>1s): adjust the light brightness during motion hold-time between 10% and 100%.
Both the adjustment by remote control and push switch can overwrite each
other, the last adjustment remains in memory.
OFF
→
ON: the light turns on and goes to auto sensor mode.
& A
4
4h
h
h
Note:the function of 24h /12h /4h /30s are disabled.
PIR
PIR
HF
PIR tangential movement 10m
HF walking across 8m
3m
PIR
HF
B
4m
HF walking across 8m
PIR tangential movement 10m
3m
PIR
HF
A
3m
HF walking across 8m
PIR tangential movement 5m