background image

                                                                                                                                 

TM-800 UHF SERVICE MANUAL

 

 

146 

 

9.CDCSS 

Balance 

Each Ch corresponds 

to a specific TX Freq, 

enter adjustment item 

“4” 

Radio 

Communication 

Test Set   

FILTER 

LPF: 300Hz 

ANT 

Change 
CDCSS 
settings with 
Selector Knob

 

Check 
waveform

10. CTCSS 

Deviation 

Each Ch corresponds 

to a specific TX Freq, 

enter adjustment item 

“5”, adjust 

67Hz/127.3Hz/254.1Hz

CTCSS 

Radio 

Communication 

Test Set   

FILTER 

LPF: 300Hz 

ANT 

Change CTCSS 

settings with 

Selector Knob 

Adjust deviation to 

0.75KHz±0.10KHz (W) 

0.37KHz±0.05KHz (N) 

 

11. CDCSS 

 Deviation 

Each Ch corresponds 

to a specific TX Freq, 

enter adjustment 

item“6” 

Radio 

Communication 

Test Set   

FILTER 

LPF: 300Hz 

ANT 

Change 
CDCSS 
settings with 
Selector Knob

Adjust deviation to 

0.75KHz±0.10KHz (W) 

0.37KHz±0.05KHz (N) 

 

12. DTMF 

Deviation 

Each Ch corresponds   

to a specific TX Freq, 

enter adjustment item 

“7” 

Radio 

Communication 

Test Set   

FILTER 

LPF: 3KHz 

ANT 

Change 
DTMF 
settings with 
Selector Knob

3.0KHz±0.1KHz (W) 

1.5KHz±0.1KHz (N) 

 

13. MSK 

Each Ch corresponds   

to a specific TX Freq, 

enter adjustment item 

“8” 

Radio 

Communication 

Test Set   

FILTER 

LPF: 3KHz 

ANT 

Change MSK 
settings with 
Selector Knob

3.0KHz±0.1KHz (W) 

1.5KHz±0.1KHz (N) 

 

14. 2-TONE/ 

5-TONE 

Each Ch corresponds 

to a specific TX Freq, 

enter adjustment item 

“9” 

Radio 

Communication 

Test Set   

FILTER 

LPF: 3KHz 

ANT 

Change 2-tone/

5-tone settings 

with Selector 

Knob 

Adjust deviation to 

3.0KHz±0.10KHz (W) 

1.5KHz±0.1KHz (N) 

 

Содержание tm-800

Страница 1: ...nd click Open download starts Click End when download is completed Turn the radio off and remove the programming cable 2 Initialization It s necessary to set the frequency and initialize the radio before adjustment because there is no needed information in FLASHROM when the radio is manufactured Turn the power on while holding down PF2 then press PF3 PF4 and PF6 in sequence The LED on control pane...

Страница 2: ...491 75 515 25 503 00 503 20 503 40 5 U5 TX MHz 503 00 480 00 526 00 491 70 515 20 503 00 503 20 503 40 RX MHz 425 15 400 15 449 85 412 55 437 55 425 00 425 20 425 40 6 U6 TX MHz 425 00 400 00 450 00 412 50 437 50 425 00 425 20 425 40 VCO Measurement Adjustment Item Condition Test Instrument Terminal Part Method Specification Remarks 1 Power supply 1 Power supply voltage DC13 6V Note 1 This radio m...

Страница 3: ...ion Test Set Ammeter ANT Adjust software setting first value is 220 and VR101 press PF6 to save and enters the next item Low power PO 5 0 5W I 5 0A Check Low power Check deviation at CH L C H 3 75 0 1KHz W 6 Max Deviation 1 Each Ch corresponds to a specific TX Freq enter adjustment item 3 turn to CH C CH L CH H CH nC Radio Communication Test Set FILTER 0 05 15KHz AF 1KHz 50mV ANT MIC Jack Adjust s...

Страница 4: ...o Communication Test Set FILTER LPF 300Hz ANT Change CDCSS settings with Selector Knob Adjust deviation to 0 75KHz 0 10KHz W 0 37KHz 0 05KHz N 12 DTMF Deviation Each Ch corresponds to a specific TX Freq enter adjustment item 7 Radio Communication Test Set FILTER LPF 3KHz ANT Change DTMF settings with Selector Knob 3 0KHz 0 1KHz W 1 5KHz 0 1KHz N 13 MSK Each Ch corresponds to a specific TX Freq ent...

Страница 5: ...n to CH1 C corresponds to a specific RX Freq Radio Communication Test Set SSG output 47dBm MOD 1KHz DEV 3KHz W 1 5KHz N FILTER 0 3 3 0KHz ANT SP Jack L135 Adjust the L135 make SINAD is max The max volume 4 6V or higher 1 CH RX Center turn to CH1 C in manual adjust mode 2 CH RX LO turn to CH2 L in manual adjust mode 17 Sensitivity 3 CH RX HI turn to CH3 H in manual adjust mode Radio Communication T...

Страница 6: ...ettings at SQL3 and SQL9 press PF6 to save Press PF2 to adjust software settings open the squelch while the value is changeless Radio Communication Test Set SSG output 122dBm level 3 19 SQ Close Enter adjustment item 12 turn to CH H CH C CH L SSG output 114dBm level 9 ANT SP Jack Adjust software setting Adjust software settings at SQL3 and SQL9 press PF6 to save Press PF2 to adjust software settin...

Страница 7: ...C 5V 2 E Ground 3 LCDCK Clock output for LCD driver 4 LCDW LCD data write 5 LCDR LCD data read 6 LCDCS LCD control signal output 7 LCD LCD display contrast 8 LAMP Power for backlight J504 To DISPLAY UNIT 1 ME MIC ground 2 MIC MIC signal output 3 E Ground 4 REST Reset signal input 5 TXD2 Serial data output 6 RXD2 Serial data input 7 E Ground 8 PSW Power switch control signal output 9 SB Power input...

Страница 8: ... control signal output 9 SB Power input after power switch 13 6V 15 10 SP1 BTL input for remote speaker output 11 SP2 BTL input for remote speaker output J104 To VCO UNIT 1 ST TX RX switch 2 HT RF output 3 E GND 4 8C 8V 5 MD Modulate output 6 CV Control voltage J108 To POWER 1 B 13 6V 0 5V J110 To EXTSP Pin No Name Description 1 OUT2 Output to speaker 2 SP2 BTL input for remote speaker output 3 SP...

Страница 9: ...condary Development Interface or Data Encryption and Decryption 1 8C 8V 2 E GND 3 SB Power input after power switch 13 6V 15 4 AUX1 Programmable auxiliary port 5 AUX6 Programmable auxiliary port 6 AUX7 Programmable auxiliary port 7 NC No Connection 8 RSSI Receiver Signal Strength Indication 9 CTO CDCSS signal output 10 PCO Transmitting Power Control Output 11 UL Unlock detection signal output 12 M...

Отзывы: