4.3 Installation Preparations
4.3.1 Environment Requirements
Space Requirements
Keep a space of at least 200 mm above the RRU.
Keep a space of at least 500 mm below the RRU.
Keep a space of at least 200 mm at the left and right sides of the RRU.
Keep a space of at least 800 mm in front of the RRU.
Install the RRU vertically at the correct position.
Grounding Requirements
Be sure to ground the equipment before installing it; disconnect the ground wire finally when removing
the equipment.
Do not destroy the grounding conductor.
Do not operate the equipment when the grounding conductor is not installed.
Connect the equipment to the protection ground permanently. Before operating the equipment, check
its electrical connection and make sure that the equipment has been grounded reliably.