![Hytera PD40Xi Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/hytera/pd40xi/pd40xi_manual_2194570021.webp)
20
Troubleshooting
Phenomena
Analysis
Solution
The radio can not be
powered on.
The battery may be
improperly installed.
Remove the battery and attach it again.
The battery may run out.
Recharge or replace the battery.
The battery may suffer from
poor contact caused by
dirtied or damaged battery
contacts.
Clean the battery contacts. If the problem
can not be solved, contact your dealer or
authorized service center for inspection and
repair.
During receiving
signals, the voice is
weak, discontinuous or
totally inactive.
The battery strength may be
too low.
Recharge or replace the battery.
The volume may be set to a
low level.
Increase the volume.
The antenna may get loose
or may be improperly
installed.
Power off the radio, and re-install the
antenna.
The speaker may be
blocked or damaged.
Clean surface of the speaker. If the problem
can not be solved, contact your dealer or
authorized service center for inspection and
repair.
You can not
communicate with
other members.
The frequency or signaling
may be inconsistent with
that of other members.
Set your TX/RX
frequency and signaling to
the same as that of other members.
The channel type
(digital/analog) may be set
inconsistently.
Make sure all members are on the same
digital/analog channel.
You may be too far away
from the group members.
Move towards other members.