  9   

4. Basic Operations 

4.1 Turning On or Off the Repeater 

 

If the repeater is connected to a DC power supply, press the power switch on the DC power supply to turn on or 
off the repeater. 

After turn-on, if the power supply indicator turns red, the repeater goes into locked status. You must switch off 
the DC power supply for four seconds, and then switch on the power supply again. 

 

If the repeater is connected to an AC power supply, press the 

AC Power Switch

 in the rear panel to turn on or off 

the repeater. 

After turn-on, the power supply indicator turns yellow. 

4.2 Changing the Channel 

Press the 

Volume/C

 or 

Volume/Channel – 

key to change the channel. 

The current channel number appears on the display of the repeater. 

4.3 Adjusting the Volume 

1.

 

Long press the 

Volume/C

 key for five seconds to switch the repeater from channel mode to volume 

mode. 

2.

 

Press the 

Volume/C

 or 

Volume/Channel –

 key to increase or decrease the volume. 

If you do not have any operation for greater than five seconds or if you long press the 

Volume/C

 key again 

within five seconds, the repeater switches to channel mode. 

4.4 Checking the Status 

4.4.1 Repeater 

Indicator 

Description 

Repeater Status 

Digital Mode 

Blue 

The repeater is operating in digital mode. 

Analog Mode 

Yellow 

The repeater is operating in analog mode. 

Alarm 

Red 

The repeater is not working properly, and the display shows the 
alarm code. 

Timeslot A TX 

Red 

 

Analog mode: The repeater is transmitting. 

Содержание HR106X

Страница 1: ...cent Unit 11 Richmond Hill ON L4B 3E6 905 305 7545 www hytera ca info hytera ca Hytera US Inc 1363 Shotgun Road Sunrise FL 33326 954 846 1011 www hytera us info hytera us C 2022 Hytera Communications...

Страница 2: ...a description of the functions and step by step procedures for use To avoid bodily injury or property loss caused by incorrect operation please carefully read the Safety Information Booklet before use...

Страница 3: ...us technology development No part of this manual may be copied modified translated or distributed in any manner without the express written permission of us We do not guarantee for any particular purp...

Страница 4: ...mined by turning it off and then on The user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separatio...

Страница 5: ...least 105 cm indoor or 180 cm outdoor away from your body in accordance with the requirements of the antenna manufacturer supplier EU Regulatory Conformance As certified by the qualified laboratory th...

Страница 6: ...tion Tasks 7 3 2 1 Preparing the Tools 7 3 2 2 Checking the Power Supply 7 3 3 Installation Procedure 7 3 4 Post installation Check 8 4 Basic Operations 9 4 1 Turning On or Off the Repeater 9 4 2 Chan...

Страница 7: ...2 Solution 15 5 7 Network IP Conflict Alarm 15 5 7 1 Description 15 5 7 2 Solution 15 5 8 Slave Unregistered Alarm 15 5 8 1 Description 15 5 8 2 Solution 15 5 9 Repeater Disabled Alarm 15 5 9 1 Descr...

Страница 8: ...gue names and hardware buttons To save the configuration click Apply The Log Level Settings dialogue appears Press the PTT key Denotes messages directories file names folder names and parameter values...

Страница 9: ...the following items If any item is missing or damaged contact your dealer Item Quantity PCS Item Quantity PCS Repeater 1 Documentation Kit 1 Power Cord 1 Figures in this manual are for reference only...

Страница 10: ...ent Display 11 Digital Mode Indicator 5 Alarm Indicator 12 Audio Programming Interface 6 Timeslot B RX Indicator 13 Air Inlet for Power Supply 7 Timeslot B TX Indicator 2 2 Rear Panel 2 2 1 Basic Vers...

Страница 11: ...tor Tuning Interface 8 DC Power Inlet 3 Accessory Connector 9 AC Power Inlet 4 RX Antenna Connector 10 AC Power Switch 5 Ethernet Interface 1 11 Ground Screw 6 Ethernet Interface 2 In routing mode the...

Страница 12: ...5 2 3 Internal Parts 2 3 1 Basic Version No Part Name No Part Name 1 PA Module 5 Wind Scooper 2 Main Board 6 Fan 3 Network Board 7 Control Panel 4 Power Supply Module 8 Float Charging Board...

Страница 13: ...6 2 3 2 Advanced Version No Part Name No Part Name 1 PA Module 5 Wind Scooper 2 Main Board 6 Fan 3 Coprocessor 7 Control Panel 4 Power Supply Module 8 Float Charging Board...

Страница 14: ...be installed in a rack bracket and cabinet or on a desk For more information refer to the Safety Information Booklet 3 2 Pre installation Tasks 3 2 1 Preparing the Tools Phillips screwdriver T 10 tor...

Страница 15: ...AC power supply powers the repeater and also charges the battery when the AC power supply malfunctions the battery works as a UPS battery to power the repeater 4 Ground the repeater through the ground...

Страница 16: ...key to change the channel The current channel number appears on the display of the repeater 4 3 Adjusting the Volume 1 Long press the Volume Channel key for five seconds to switch the repeater from ch...

Страница 17: ...ter is receiving on timeslot B 4 4 2 Network Interface Indicator Description Repeater Status Ethernet Interface LED 1 Flashing The network interface card is transmitting data LED 2 Glowing The data tr...

Страница 18: ...X unlocked alarm The repeater fails to work At this time if the Repeater Backup feature is enabled on the CPS the repeater starts a backup E6 Power amplifier PA over temperature alarm The repeater fai...

Страница 19: ...r stops transmission 5 1 2 Solution Check whether the RF adapter cable antenna or feed line is properly connected If yes contact your local dealer for technical support If no re connect or replace the...

Страница 20: ...tions of the repeater meet the installation requirements If yes proceed with Step 3 If no take the appropriate measure e g air conditioner to reduce the ambient temperature and improve ventilation 3 C...

Страница 21: ...e DC power supply If the repeater is powered by the DC power supply replace the DC power supply or connect the repeater to the DC power supply 5 5 VSWR Alarm 5 5 1 Description When the repeater detect...

Страница 22: ...m code H3 appears on the display At this time network services of the repeater are unavailable 5 7 2 Solution Check and modify the network configuration 5 8 Slave Unregistered Alarm 5 8 1 Description...

Страница 23: ...ransforms between active and invalid status the repeater restarts 5 9 2 Solution Contact your local dealer for technical support 5 10 Off lease Alarm 5 10 1 Description When the rental time of the rep...

Страница 24: ...ove towards the communication coverage of the repeater The repeater works properly but the radio cannot communicate with the other radios in the same group even though the RX indication is given The C...

Страница 25: ...m substances that can corrode the circuitry Do not place the product in corrosive agents solutions or water 7 2 Product Cleaning Turn off the product before cleaning Clean up the dust and fine particl...

Страница 26: ...ontact your local dealer for the optional accessories used with the product Use the accessories specified by the Company only Otherwise we will not be liable for any loss or damage arising out of use...

Страница 27: ...iversal Serial BUS VSWR Voltage Standing Wave Ratio WAN Wide Area Network Hytera Canada 100 Leek Crescent Unit 11 Richmond Hill ON L4B 3E6 905 305 7545 www hytera ca info hytera ca Hytera US Inc 1363...

Отзывы: