TM-800K Service Manual
86
11. CDCSS
Deviation
Each Ch
corresponds to a
specific TX Freq,
enter adjustment
item “6”
Radio
Communication
Test Set
FILTER
LPF: 300Hz
ANT
Change
CDCSS
settings with
Selector
Knob
Adjust deviation to
0.75KHz±0.10KHz
(W)
0.60KHz±0.05KHz
(M)
0.37KHz±0.05KHz
(N)
12. DTMF
Deviation
Each Ch
corresponds to a
specific TX Freq,
enter adjustment
item “7”
Radio
Communication
Test Set
FILTER
LPF: 3KHz
ANT
Change
DTMF
settings with
Selector
Knob
3.0KHz±0.1KHz (W)
2.4KHz±0.1KHz (M)
1.5KHz±0.1KHz (N)
No need to
adjust
13. MSK
Each Ch
corresponds to a
specific TX Freq,
enter adjustment
item “8”
Radio
Communication
Test Set
FILTER
LPF: 3KHz
ANT
Change
MSK
settings with
Selector
Knob
3.0KHz±0.1KHz (W)
2.4KHz±0.1KHz (M)
1.5KHz±0.1KHz (N)
14.
2-Tone /
5-Tone
Each Ch
corresponds to a
specific TX Freq,
enter adjustment
item “9”
Radio
Communication
Test Set
FILTER
LPF: 3KHz
ANT
Change
2-tone /
5-tone
settings with
Selector
Knob
Adjust deviation to
3.0KHz±0.10KHz (W)
2.4KHz±0.1KHz (M)
1.5KHz±0.1KHz (N)
Receiver
Measurement
Adjustment
Item
Condition
Test Instrument Terminal Part
Method
Specification
/ Remarks
UHF:
15. RF
bandpass filter
Enter adjustment
item “10”,
each Ch corresponds
to a specific RX Freq
Scanner ANT.
TP1
Adjust
software
settings
Adjust the gain to the
Max. value, the
corresponding freq is
on the leftmost (UHF)
or rightmost (VHF) to
bandpass waveform.
Press
[ PF6 ]
to save.
VHF:
Содержание TM-800K
Страница 1: ......
Страница 83: ...TM 800K Service Manual 81...
Страница 100: ...TM 800K Service Manual 98 Exploded View...
Страница 102: ...TM 800K Service Manual 100 Packing...
Страница 103: ...101...
Страница 104: ...102...
Страница 105: ...103...
Страница 106: ...104...
Страница 107: ...105...
Страница 108: ...106...
Страница 128: ......