![HYT TC-610P Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/hyt/tc-610p/tc-610p_service-manual_2194358010.webp)
TC-610P Service Manual
8
(3) If any abnormal situation occurs during cloning, the source radio will stop cloning and its LED will go
out, indicating both radios are ready for another cloning operation.
(4) When cloning ends, the source radio goes back to the standby status. Press
SK2
again to begin
another cloning operation.
Manual Adjust Mode
Turn on the radio with
PTT
and
SK2
held down to enter Manual Adjust Mode.
Note: This operation is subject to the option Panel Test Mode in the programming software. When this
option is unchecked, the radio is unable to enter the adjustment mode, which helps avoid change of
parameters and degradation of radio performance caused by user’
s misoperations.
Keep this option unchecked after values are well adjusted from factory, to avoid any unexpected change
of values. The adjustment values can be reset and changed in Factory Mode only.
Description of adjustment:
1) To enter Manual Adjust Mode
Turn on the radio with
PTT
and
SK2
held down for above 2 seconds. Then the LED glows orange to
indicate that the radio enters Adjustment Mode.
When the keys are released, the radio will enter item N of Tx group (N depends on the position where
the
Channel Selector Knob
locates). The radio enters an item of Tx group by default, and the LED
glows red. (CH16 is used to switch between Tx group items and Rx group items. When the
Channel
Selector Knob
locates at channel 16, there is no LED indication.)
2) To switch between Tx group and Rx group
Turn the
Channel Selector Knob
to channel 16, and then long press
PTT
to switch between Tx group
and Rx group. Red LED glows when Tx group is selected, and green LED glows when Rx group is
selected.
3) To switch between items of Tx group/Rx group
This operation is done through the
Channel Selector Knob
.
Tx group: CH1~Ch14 respectively represent Tx Preset Power, Tx Low Power, Tx Medium Power, Tx
High Power, CDCSS Deviation, CTCSS Deviation (low), CTCSS Deviation (medium), CTCSS Deviation
(high), MSK Deviation, VOX Level 1, VOX Level 2, VOX Level 3, VOX Level 4, VOX Level 5 and Tx Low
Voltage Threshold. Note: MSK Deviation is available to HDC1200 model only.