TC-610/620 Service Manual
64
Rotate
to
CH9.
VOX 1
Press SK1 or
SK2 to enable
the function.
Radio
communication
test set
BPF:
<20Hz~15kHz
AF:1kHz
10mV
Adjust with SK1/SK2 and
rotate the Channel
Selector knob to save
after one-point adjustment.
Rotate to
CH10.
VOX 2
Press SK1 or
SK2 to enable
the function.
Radio
communication
test set
BPF:
<20Hz~15kHz
AF:1kHz
6mV
Adjust with SK1/SK2 and
rotate the Channel
Selector knob to save
after one-point adjustment
Rotate to
CH11.
VOX 3
Press SK1 or
SK2 to enable
the function.
Radio
communication
test set
BPF: <
20Hz~15kHz
AF:1kHz
4.5mV
Adjust with SK1/SK2 and
rotate the Channel
Selector knob to save
after one-point adjustment
Rotate to
CH12
VOX 4
Press SK1 or
SK2 to enable
the function.
Radio
communication
test set
BPF: <
20Hz~15kHz
AF:1kHz
3.5mV
Adjust with SK1/SK2 and
rotate the Channel
Selector knob to save
after one-point adjustment
VOX
Rotate to
CH13.
VOX 5
Press SK1 or
SK2 to enable
the function.
Radio
communication
test set
BPF:
<20Hz~15kHz
AF:1kHz
2mV
Antenna
Accessory
jack
SK1
SK2
Adjust with SK1/SK2 and
rotate the Channel
Selector knob to save
after one-point adjustment
Tx Low
Voltage
Threshold
Digital
voltmeter
Power
supply
port
Power
supply
Adjust the output voltage
of the power supply and
check the alarm level
6.2V-7.0V
(
≤
7.0V: LED
flashes;
≤
6.2V: a
warning tone
is heard and
transmission
is suspended)
Rotate to
CH8.
Low
frequency
Rx
Sensitivity
(bandpass)
Short press
PTT to switch
to other
frequencies.
Radio
communication
test set
SSG:
-119dBm
MOD: 1KHz
DEV: 3.0KHz
Filter: 0.3
~
3KHz
Antenna
Accessory
jack
SK1
SK2
Check bandpass waveform.
Adjust with SK1/SK2.
Rotate the Channel
Selector knob to save
after five-point
adjustment.
Check: Rotate
the Volume
Control knob
to an
appropriate
position to
make the
output
unlimited.
SINAD:
≥
12dB
Содержание TC-610
Страница 9: ...TC 610 620 Service Manual 69 Troubleshooting Flow Chart Tx Section ...
Страница 10: ...TC 610 620 Service Manual 70 Rx Section ...
Страница 11: ...TC 610 620 Service Manual 71 MCU ...