MAINTENANCE
NARROW AISLE
50
MAINTENANCE PROCEDURES
CHECKS WITH THE KEY SWITCH OFF
Hydraulic System
Inspect the hydraulic system for leaks and damaged or
loose components.
WARNING
At operating temperature the hydraulic oil is HOT. Do
not permit the oil to contact the skin and cause a burn.
CAUTION
Do not permit dirt to enter the hydraulic system when the oil
level is checked or the filter is changed. Never operate the
pump without oil in the hydraulic system. The operation of
the hydraulic pump without oil will damage the pump.
Check the hydraulic oil level when the oil is at operating
temperature, the carriage is lowered, the reach mechanism
retracted and the key switch is in the
OFF
position.
Table 2 -- Hydraulic Oil Tank Capacities
BATTERY
COMPARTMENT SIZE
OIL TANK CAPACITY
TO FULL MARK
318 mm (12.5 in)
21.6 litres (5.70 gal)
371 mm (14.6 in)
23.5 litres (6.22 gal)
422 mm (16.6 in)
25.5 litres (6.73 gal)
478 mm (18.8 in)
29.3 litres (7.74 gal)
536 mm (21.1 in)
29.3 litres (7.74 gal)
Hydraulic System
=
Tank Capacity
+
4.01 litres
(1.06 gallons) in lines
Add hydraulic oil only as needed. Be careful not to add too
much. If more hydraulic oil is added than the FULL level, the
hydraulic oil will leak from the breather during operation.